background image

Note:

  Illustrations depict components as

equipped when specified lift series was in
production.  Replacement components
may reflect newer lift series configurations.

Revised:  2-9-04

Page 9

Series

 02 

CL917IB Supplement

 30067

Page 9

Century

 Series

™ 

02 

CL917IB 

Supplement 30067

Series

 02 

CL917IB 

Lift Exploded View

61

62

59

65

66

67

61

62

60

91

91

93

80

84

117

117

92

92

91

86

87

88

90

85

94

94

89

95

53

114

111

68

54

109

104

113

53

53

53

50

116 

55

70

53

53

109

111

80

157

14

16

153

77

139

7  

139

67

91

76

105

149

149

105

68

98

130

91

91

92

91

92

87

86

91

90

117

117

79

113

53

53

50

94

89

95

150

116

15

14

126

91  

157

76

63

79

101

10

130

93

94

94

152

151

16

153

85

77

38

102

15

85

115

115

115

85

126

79

63

9

101

149

107

99

91

91

99

66

132

132

5

94

152

121

155

118

137

135

131

133

120

129

136

137

129

122

123

136

137

138

137

119

135

6

66

128

125

128

138

131

71

71

141

64

71

88

56

57

97

71

71

71

141

58

38

102

82

81

82

84

81

74

106

66

144

127

124

67

64

58

58

149

58

58

58

71

71

67

107

19

22

23

20

26

30

31

3

32

29

33

108

34

2

35

21

39

24

83

112

104

113

112

4

112

74

106

74

106

110

110

154

147

58

58

57

33

91

91

1

78

98

98

52

52

52

156

52

52

52

51

25

25

134

52

52

73

52

114

52

52

72

103   

103 

69

49 

52

52

52

51

134

52

52

72 

12

74

12

11

13

106

74

106

27

28

18

14

15

14

158

27

100

17

16

28

17

100

18

74

106

74

106

27

28

14

16

14

15

17

17

159

27

28

78

134

12

36

37

37

43

47

38

39

41

46

46

48

41

47

40

45

47

43

46

44

41

42

38

39

145

76

66 

75

145

66 

76

75

98

74

106

74

106

74

106

113

79

27

28

27

28

27

28

27

28

27

28

27

28

133

140

142

143

143

142

140

146

148

96

47

8

160

161

161

148

148

162

163

163

Содержание CENTURY CL917IB

Страница 1: ...WARNING Read manual before installing or servicing lift Failure to do so may result in serious bodily injury and or property damage ual Man...

Страница 2: ...the lift examine the unit for any damage Notify the carrier at once with any claims Two warranty registration cards shown right are located in the lift mounted manual storage pouch The sales represent...

Страница 3: ...ies 03 lift model read this supplement as well as all informa Subject CL917IB Century Series 03 Lift Models Effective October 2003 tion contained in this manual and additional supplements if included...

Страница 4: ...stainless steel Allen adjustment screws to reposition the limit switches Adjust these microswitches as outlined below and on Microswitch Adjustment Instructions decal 24490 posted on tower Turn adjust...

Страница 5: ...unted Platform Sensor Pressure Switch J2 J6 J4 J13 Red J14 White Y GN Fold Unfold Switch GN BK W BN Up Down Switch Switch Box As Viewed From Terminal Side of Switch BK R BK W NOT USED GREEN 6 COND WHI...

Страница 6: ...39 17 1 Strain Relief SR 7W 2 See note below 7A 7B and 7C only 11352 11352 18 1 Cover Switch Box See note below 26798 26798 19 1 Power Cable Millennium Up Solenoid to Motor 29049 29049 20 1 Solenoid 4...

Страница 7: ...2 50 57 17 6 12 8 9 10 11 7C 7B 46 7A DO WN UP UN FO LD O UT FOLD IN 13 14 15 16 16 18 22 2 32 38 64 63 Series 03 CL917IB Pump Module Diagram Apply red 271 Thread Locker Loctite to the three pump moun...

Страница 8: ...3701A 71 8 Screw 10 24 x 1 2 Button Head Allen 25842 72 2 Tube Weldment Lower Fold Arm W O Microswitch 916 0426RW 73 1 Weldment Tube Upper Fold Arm Front 975 2425FRW 74 10 Washer 1 2 Flat Black Zinc 2...

Страница 9: ...25 128 138 131 71 71 141 64 71 88 56 57 97 71 71 71 141 58 38 102 82 81 82 84 81 74 106 66 144 127 124 67 64 58 58 149 58 58 58 71 71 67 107 19 22 23 20 26 30 31 3 32 29 33 108 34 2 35 21 39 24 83 112...

Страница 10: ...U n f o l d f o r S e r i e s 0 3 C L 9 1 7 I B L i f t E x p l o d e d V i e w Century Series 03 CL917IB Supplement 30304...

Страница 11: ...the inboard end of the platform resulting in an unsafe platform angle Subject CL917IB Century Series 02 Lift Models featuring Bridging capability Effective September 2003 Service Refer to this supple...

Страница 12: ...CIRCUIT BREAKER RD 4 RD 2 RD 2 RD 14 GN 14 UNFOLD FOLD UP DN SWITCH BOX WH 16 BK 16 BN 16 YL 16 GN 16 GN 16 LIFT HYDRAULIC UP M GROUND BAT AUX POWER STUD PUMP BODY GROUND BATTERY RD DOWN SOLENOID M B...

Страница 13: ...Pump Only PIN 2 R BK Pump Mounted Platform Sensor Pressure Switch J2 J6 J4 J13 Red J14 White Y GN Fold Unfold Switch GN BK W BN Up Down Switch Switch Box As Viewed From Terminal Side of Switch BK R BK...

Страница 14: ...is a black and red wire with 1 4 insulated male spade terminals d Plug the ground source from customer sup plied remote interlock with the 1 4 insulated female spade connector into the 1 4 insulated m...

Страница 15: ...terminals d Plug the 12V source from remote interlock into red wire supplied with insulated male spade connector e Remove male interlock jumper from front of pump module cover Store in glovebox for u...

Страница 16: ...ips See note below 24739 24739 17 1 Strain Relief SR 7W 2 See note below 7A 7B and 7C only 11352 11352 18 1 Cover Switch Box See note below 26798 26798 19 1 Power Cable Millennium Up Solenoid to Motor...

Страница 17: ...2 50 57 17 6 12 8 9 10 11 7C 7B 46 7A DO WN UP UN FO LD O UT FOLD IN 13 14 15 16 16 18 22 2 32 38 64 63 Series 02 CL917IB Pump Module Diagram Apply red 271 Thread Locker Loctite to the three pump moun...

Страница 18: ...rm Front 975 2425FRW 74 10 Washer 1 2 Flat Black Zinc 25346 75 2 Bolt 3 8 16 x 1 Hex 10025 76 6 Washer 3 8 Lock Black 10069BK 77 2 Lever Inboard Barrier 975 0404 78 2 Clamp Insulate 1 3 8 I D 29765 79...

Страница 19: ...79 63 9 101 149 107 99 91 91 99 66 132 132 5 94 152 121 155 118 137 135 131 133 120 129 136 137 129 122 123 136 137 138 137 119 135 6 66 128 125 128 138 131 71 71 141 64 71 88 56 57 97 71 71 71 141 58...

Страница 20: ...U n f o l d f o r S e r i e s 0 2 C L 9 1 7 I B L i f t E x p l o d e d V i e w Century Series 02 CL917IB Supplement 30067...

Страница 21: ...uctions 28 29 Floor Level Guideline Adjustments 30 31 Quiet Ride Adjustment Instructions 32 33 Maintenance and Lubrication Lubrication Diagram 34 Maintenance and Lubrication Schedule 35 37 Systems Des...

Страница 22: ...tform Pivot Fold Arms 2 Rotating Pivot Slide Arms 2 Platform Side Plates 2 Vertical Arm Covers 4 Pump Side Cylinder Base Plate Pump Module Rear Automatic Inboard Roll Stop and Bridge Plate IB Opposite...

Страница 23: ...nd held control switchbox is connected to the pump module Quick disconnect hand held controls are available with three types of cable standard armored and coiled The control box is equipped with two c...

Страница 24: ...Symbols SAFETY FIRST Know That C CAUTION This symbol indicates important information regarding how to avoid a hazardous situation that could result in minor per sonal injury or prop erty damage The in...

Страница 25: ...contained in this manual Disconnect the power cable at the battery prior to servicing Keep hands arms and all other body parts clear of moving parts Never modify alter a Braun Corporation lift Replace...

Страница 26: ...g area prior to begin ning installation procedures Failure to do so may result in serious bodily injury and or property damage Obstructions Any obstructions within the door opening such as additional...

Страница 27: ...ned on pages 18 and 19 Vehicle Battery Ground Cable The external battery ground cable supplied with the lift must be connected to the same vehicle framing member that the pump ground cable is attached...

Страница 28: ...77 4 2 Bolt 3 8 16 x 1 Hex 10025 5 8 Washer 2 469 O D x 5 I D Flat 13342 6 14 Washer 3 8 Flat 10064 7 4 Washer 3 8 Lock 10069 8 8 Washer 3 8 External Tooth Star 25844 9 2 Washer 5 16 External Tooth St...

Страница 29: ...unting hardware as specified per chassis and floor configuration Acceptable Reinforcement Bracket Positions typical either end 3 8 Lock Washer 3 8 Flat Washer 3 8 Hex Nut 6 7 9 1 3 3 3 3 Specification...

Страница 30: ...re the lift in the stowed position during shipment Before removing the shipping straps install the lift and power the platform to the fully folded position press FOLD switch When positioning the lift...

Страница 31: ...gure F The lift towers should be perpendicular 90 to the vehicle floor except when base plate shims are used details on page 12 Stepwell Installations When installing a CL917 Series lift in the side c...

Страница 32: ...and vertical arm kick out to provide adequate clearance between lift and vehicle See Figure G There must be a minimum 1 clearance between the lift vertical arms and or automatic inboard roll stop and...

Страница 33: ...ement Bracket Positions typical either end 2 Lift Securement Optimum Bolt Locations Underfloor Reinforcement Brackets Outboard Inboard Mounting Bolts Mounting Bolts Mounting Bolts Mounting Bolts Tower...

Страница 34: ...assistance If the base plate mounting holes cannot be used in your application call for technical assis tance Underfloor vehicle configuration data is available for Ford Chevy GMC and Dodge vans not a...

Страница 35: ...nderfloor brackets are used or bolts penetrate chassis subframe members Lift Installation Instructions Ford Rear Door Installations All four underfloor reinforcement brackets must be used see Figure L...

Страница 36: ...ten inside mounting bolts first then tighten outside mounting bolts Measure alignment of towers and vertical arms while tightening See Figure M Note Towers must be aligned and parallel with platform s...

Страница 37: ...to drill the grommet access hole Insert the grommet in the hole Use two self tap screws to secure the plastic grommet Power Cable A red rubber boot is supplied in the installation package to insulate...

Страница 38: ...d cable clear of lift operation Route ground cables clear of exhaust system other hot areas and moving parts Failure to do so may result in serious bodily injury and or property damage WARNING Lift In...

Страница 39: ...nal Tooth Star Washer 5 16 18 x 3 4 Thread Cutting Screw Mounting Hardware Detail Vehicle Battery Ground Cable The external battery to frame ground cable supplied with the lift must be connected to th...

Страница 40: ...tructions 4 Circuit Sentry Installation and Power Connection P Figure P Note Compact Circuit Sentry Kit 29789KS is currently supplied with 12 volt lift models Photos of the com pact Circuit Sentry ins...

Страница 41: ...les spaced 1 apart are provided in each mounting bracket The holes match the pattern of circuit breaker mount ing holes Place the bracket securely in a vice gripping the edge that does not obstruct po...

Страница 42: ...t the control box harness installed All harnesses are equipped with the same quick disconnect sockets Connect the control box harness as outlined below Harness Installation Connect Instructions 1 Alig...

Страница 43: ...ess Routing and Securement Control box cable routing and securement varies according to the application Route and secure cable clear of potential door and lift damage Door opens to Pump Side Route the...

Страница 44: ...Adjustment In structions on pages 28 and 29 to achieve the proper platform angle Positioning and Clearance Checklist Vehicle Clearance Vertical arms and parallel arms must clear door opening vertical...

Страница 45: ...pages 28 and 29 Alignment Side to Side Alignment As viewed from outside the vehicle the lift vertical arms and platform when stowed should be perpendicular 90 to the vehicle floor and parallel aligne...

Страница 46: ...latform the Handrail belt must be latched Passenger must be positioned fully inside yellow boundaries Wheelchair brakes must be locked Roll stop s must be up Failure to follow these rules may result i...

Страница 47: ...Quiet Ride Guided Stop Blocks and fixed rubber bumpers mounted at key loca tions aid in eliminating or reduc ing potential rattles Improper installation procedures can result in potential rattles also...

Страница 48: ...ween the inboard end of the platform and the ground when the outboard end of the platform con tacts the ground Rear Door and Extensive Floor To Ground Installations Installations where base plate wedg...

Страница 49: ...d See Figure U on previous page Apply Loctite to adjustment screws following adjustment Loosen turn counterclock wise to lower outboard end of platform Tighten turn clockwise to raise outboard end of...

Страница 50: ...tower Floor Level Guideline Adjustments The Unfold Down and Up Fold microswitches control platform and bridge plate positioning Ensure floor level adjustments are correct as outlined on page 31 Platf...

Страница 51: ...Unfold Down microswitch setting can prevent the platform from unfolding fully during the Unfold cycle Or the Up Fold microswitch may be adjusted improperly allowing the platform to raise above floor...

Страница 52: ...rm when the lift is in the fully folded stowed position and prevents direct metal to metal contact Refer to the part numbers at the right for replacements Platform side plate securely nested in guided...

Страница 53: ...e base plate add washers shims as needed to eliminate the play Unfold the platform and remove the bumpers Add washers shims as needed and tighten the mounting hardware securely Refer to the Repair Par...

Страница 54: ...ngs 4 Points LO Roll Stop Hinge Pivot Points 2 LO See Detail C Parallel Arm Pivot Pins 8 LO See the Maintenance Lubrication Schedule for recommended applications per number of cycles or elapsed time R...

Страница 55: ...ening spring pivot points 4 Inspect Lift Tite latches and gas springs for wear or damage bent deformed or misaligned positive securement external snap rings and proper operation Inspect outboard roll...

Страница 56: ...ard roll stop lever bracket pins 1 per pin Lift Tite latch gas dampening spring 2 per spring Remove pump module cover and inspect Hydraulic hoses fittings and connections for wear or leaks Harness cab...

Страница 57: ...draulic connections for wear damage or leaks Inspect parallel arms bushings and pivot pins for visible wear or damage Inspect base plate tower parallel arm pivot pin mounting bolts 4 Inspect vertical...

Страница 58: ...Page 38 Note Note This page intentionally left blank...

Страница 59: ...ally stop at floor level as outlined discontinue lift operation immediately Contact your lift sales representative or call The Braun Corporation at 1 800 THE LIFT Systems Descriptions Maintenance and...

Страница 60: ...ding function Note When the platform reaches the stowed fully folded position the Hydraulic Platform Sensor Pressure Switch is activated pre set pressure reached The activated pressure switch shuts th...

Страница 61: ...the UP switch is pressed The FOLD In switch circuit is interupted when the platform is below floor level The Up Fold microswitch is deactivated when the platform reaches floor level This interrupts th...

Страница 62: ...rical Down Solenoid Hydraulic Valve The UNFOLD switch circuit Hydraulics energizes this solenoid valve which allows hydraulic fluid to return from the cylinders to the reservoir at a limited rate thus...

Страница 63: ...Unfold and lower the platform to the ground Place a 75 pound load in the center of the platform and raise the platform to floor level 2 Press the IN Fold switch If the pump shuts off and the platform...

Страница 64: ...ing normal operation The orifice meters the rate of oil flow from the lift cylinder in the event there is an external hydraulic fluid leak between the elbow and the pump preventing rapid platform desc...

Страница 65: ...remature failure of new seals Replace cylinder if tests indicate failure Failure to do so may result in serious bodily injury and or property damage WARNING Troubleshooting Replacement of the cylinder...

Страница 66: ...ch until lift is fully folded then unfold platform Adjust or replace See Microswitches in Systems Descriptions for details page 41 Connect repair or replace Replace pump Check for loose connection or...

Страница 67: ...or damage to Parallel arms and or pivot pins Rotating pivot slide arms and or pivot pins Handrails and or pivot pins Platform fold axles Platform pivot pins lower fold arms 2 23 Mechanical binding 2...

Страница 68: ...sive load 5 33 See 3 20 5 16 and 5 20 5 41 Backup pump release valve contamination 5 42 See 5 11 and 5 20 5 51 See 5 13 5 61 See 2 22 2 23 2 24 2 27 5 62 Air in hydraulic lines Correct or replace Corr...

Страница 69: ...ed against Lift Tite latches 8 11 Slide support arm guide bolts improperly adjusted tightness missing or damaged 8 12 Worn bushings pivot pins 8 13 Pivot pins misaligned hardware missing or otherwise...

Страница 70: ...TTERY CHASSIS GROUND CIRCUIT BREAKER CONNECTORS JUNCTION MOTOR MICROSWITCH PRESSURE SWITCH DIODE SWITCH SOLENOID SYMBOL DESCRIPTION SOLENOID 5 1 3 2 4 5 J2 10 1 2 11 8 6 7 9 4 12 3 5 J5 10 1 2 11 8 6...

Страница 71: ...o Restraint Belt Front Pump Only PIN 2 R BK Pump Mounted Platform Sensor Pressure Switch J2 J6 J4 J13 Red J14 White Y GN Fold Unfold Switch GN BK W BN Up Down Switch Switch Box As Viewed From Terminal...

Страница 72: ...Plug the ground source from customer supplied remote interlock with the 1 4 insu lated female spade connector into the 1 4 insulated male spade connector on the black wire exiting the back side of the...

Страница 73: ...he 12V source from remote interlock into red wire supplied with insulated male spade connector e Remove male interlock jumper from front of pump module cover Store in glovebox for use if needed when t...

Страница 74: ...COLOR NO 9 COND WIRE CODE 7 8 9 Switch Box As Viewed From Terminal Side of Switch 1 2 3 4 5 6 7 8 9 18 Gauge Lift Control Box Wiring Diagram Note Applicable for 18 gauge wiring harness control box 90...

Страница 75: ...Orifice M Unfold Orifice Unfold Valve Pump Fixed Displacement Reservoir Vented Backup Pump Cylinder Single Acting Check Valve Manual Shutoff Valve Pressure Compensated Flow Control Orifice 2 Way 2 Po...

Страница 76: ...2 1 Clamp Reservoir H 48 M259 17069 13 1 Reservoir Hydraulic Fluid 16934 14 1 Cap Reservoir Filler 16935 15 1 Connector Plastic Y 1 8 O D 18877 16 1 Switch Pressure 1600 PSI 7 16 20 SAE O Ring Male 26...

Страница 77: ...m Note See page 55 for CL917 Hydraulic Schematic 23 Opposite Pump Cylinder Hydraulic Pump Manual Backup Pump 22 20 21 17 9 11 16 12 22 23 19 18 26 15 14 1 13 5 2 3 6 4 7 10 24 25 24 Hydraulic Pump Mot...

Страница 78: ...Strain Relief SR 7W 2 See note below 7A 7B and 7C only 11352 11352 18 1 Cover Switch Box See note below 26798 26798 19 1 Power Cable Millennium Up Solenoid to Motor 29049 29049 20 1 Solenoid 4 Post 28...

Страница 79: ...T FOLD IN 13 14 15 16 16 18 22 2 32 38 63 Pump Module Diagram Apply red 271 Thread Locker Loctite to the three pump mounting bolts items 41 and 42 if a blue nylon patch is not present on the bolts whe...

Страница 80: ...r Fold Arm Front 975 2425FRW 74 10 Washer 1 2 Flat Black Zinc 25346 75 2 Bolt 3 8 16 x 1 Hex 10025 76 6 Washer 3 8 Lock Black 10069BK 77 2 Lever Inboard Barrier 975 0404 78 2 Clamp Insulate 1 3 8 I D...

Страница 81: ...123 136 137 138 137 119 135 6 66 128 125 128 138 131 71 71 141 64 71 88 56 57 97 71 71 71 141 58 38 102 82 81 82 84 81 74 106 66 144 127 124 67 64 58 58 149 58 58 58 71 71 67 107 19 22 23 20 26 30 31...

Страница 82: ...tform reaches ground level and roll stop unfolds fully 3 Unlatch handrail belt 4 Unlock wheelchair brakes and unload passenger from platform TO LOAD PASSENGER 1 Load passenger onto platform and lock w...

Страница 83: ...ottom of handle behind bottom clip 2 Rotate clip to lock O P E N C L O S E OPEN VALVE CLOSE UNLOCK LOCK Actual Size 1 5 16 Wide x 5 8 Tall Actual Size 2 1 16 Wide x 5 Tall WARNING Adjust switch as spe...

Страница 84: ...endent on lift model Order as needed Note Clean surfaces as detailed on page 61B before antiskid application Size Color Part No 2 x 12 Black 24172 BK 2 x 12 Yellow 24172 YL 3 x 12 Black 24173 BK 3 x 1...

Страница 85: ...rovided on the back cover of this manual The warranty cards must be processed to activate the warranty Two Braun Serial No Series No identification tags are posted on the lift One I D tag shown below...

Страница 86: ...loor heights All figures must be calculated per your particular Length of Travel floor to ground dimension when comparing 1 Environmental temperature of 72 F Extremely low temperatures can moderately...

Страница 87: ...ull Stroke Cycle Platform Raise 48 51 strokes to 51 strokes 51 strokes 941 per Stroke Platform Fold Full Stroke Cycle 19 5 strokes to 21 strokes 20 25 strokes Full Stroke Cycle Number Average Number A...

Страница 88: ...and frame Clear Platform Length The maximum usable length of platform Clear Vertical Passageway The maximum height wheelchair or object that can pass through the lift frame with the lift at floor lev...

Страница 89: ...fined as finished door opening including any intrusive door jambs headers sills or hinges Any intrusive obstructions within the Clear Door Opening must be removed See the Pre Installation Notes for fu...

Страница 90: ...ach other page 25 point 10 Are the towers upright supports perpendicular 90 to the vehicle floor except when base plate wedges are used page 25 point 11 Viewing the lift from outside the vehicle when...

Страница 91: ...and Circuit Sentry installed as detailed on pages 17 21 Is the control box mounted to door as detailed and is the control box cable routed and secured as detailed on pages 22 and 23 Note Open and clos...

Страница 92: ...attles abnormal sounds etc Has the hand held switch box cable been damaged Do the lift control switches function properly Do the lift cargo door securement devices function as intended Is the manual b...

Страница 93: ...Over 300 Braun Dealers Worldwide Providing Access to the World Providing Access to the World International Corporate Hdqrs P O Box 310 Winamac IN 46996 USA 1 800 THE LIFT 574 946 6153 FAX 574 946 4670...

Страница 94: ......

Отзывы: