Additional programmable features of the controller are:- 

 

a) 

Two independent temperature sensing circuits 

b) 

Two independent liquid level sensing circuits 

c) 

Variable temperature hysteresis 

d) 

High/low temperature alarm circuit (no volt or 110/250volt output) 

e) 

Manual  energy  saving  function  for  overnight/weekend  shutdown  periods  (not  timer 
operated) 

f)       No volt or 110/240v output relay to operate heater / pump 

 

Please contact Braude if you require further information. 

 
 

2. 

Warning Notice 

 

We strongly recommend that installation is carried out by a qualified electrician.  This controller 
is manufactured from top quality non-corrodable materials and should give trouble free service 
provided it is installed, operated and maintained properly. 

 

Warning-Mains Voltage 

  Always disconnect supply before removing cover or attempting connections. 

  The Tankmaster MP is supplied as standard with 

Volt free

 relays UNLESS specified at 

the time of order. 

  Should the Tankmaster MP be ordered as a mains output voltage type the grey output 

lead (marked with a red warning label and fitted with a protective cap) becomes live once 
the mains supply lead is connected to 230/110VAC.  Always connect output lead first. 

  The controller is rated at 5 amps, any heater or pump likely to draw more current should 

be connected through a contactor as shown in the wiring diagrams Fig 3 or 4. 

 

Note: Failure to connect the earth may result in a serious safety hazard. 

 

  Your Tankmaster controller is sealed to IP65 standard. If the cover is removed ensure 

that  the  gasket  is  firmly  seated  in  the  locating  groove  before  tightening  the  remaining 
screws. 

 

Caution The controller must be isolated from the electrical supply during installation. 

 

 
3.  

Mounting   

 

Remove the clear plastic cover by undoing the 4 plastic screws at the corners.  The controller 
should  be  fixed  to  a  suitable  surface  within  reach  of  the  probe  leads  using  suitable  screws 
through the 4 fixing holes in the corner pillars.  The unit should be positioned within easy reach 
of the equipment to which it will be connected.  

 

 

Содержание TANKMASTER MP

Страница 1: ...E Combined Temperature and Liquid Level Controller INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS These instructions should be carefully read and understood by all operators before installing and...

Страница 2: ...roller capable of controlling liquid and temperature parameters within a process Fig 1 Tankmaster controller Wall mounting holes 4 corners Calibration Pots A B Control LED s Levelmaster HPD probe plug...

Страница 3: ...olt free relays UNLESS specified at the time of order Should the Tankmaster MP be ordered as a mains output voltage type the grey output lead marked with a red warning label and fitted with a protecti...

Страница 4: ...on Black 3 Alarm relay common This relay is volt free and any voltage between 12 and 240v may be applied across it Black 4 Alarm relay output Black 5 Level control output pump This is a volt free rela...

Страница 5: ...n in Fig 2 on page 6 has two LED displays six LED s and three push buttons The larger of the two displays referred to as the main display throughout this document displays the temperature of probe T1...

Страница 6: ...Setting the SET POINT a Press P1 once to display the SET POINT which is shown in the main LED display as SP The actual set point value is shown in the small LED display window below it b Press P2 to...

Страница 7: ...he end stops on the potentiometers otherwise damage will occur 5 7 Immersion Method Against Known Temperature Place the probe and a thermometer in a container of ice and water and allow to settle for...

Страница 8: ...ALISTS Fig 2 Temp and Liquid level status TEMPERATURE LEVEL HEATER PUMP Alarm Low Low Alarm Temperature below set point OFF ON ON Temperature above set point OFF OFF OFF Liquid level low ON OFF OFF ON...

Страница 9: ...Page 9 Date 06 09 2019 IN037 Rev 6 May 2019 THERMAL PROCESS EQUIPMENT SPECIALISTS 6 Wiring connection Fig 3 Wiring diagram for Tankmaster connected to Polaris heater Live relay...

Страница 10: ...the solution level The probe is supplied with a two or three pin IP66 standard plug which should be connected to the appropriate sockets on the underside of the controller Ensure that the locking rin...

Страница 11: ...velmaster probe 10 1 1 Low level only Cut the red sensor to the low level required Cut the white sensor 50mm higher than the low level sensor Cut the green sensor to not less than 30mm below the lowes...

Страница 12: ...s supplied with your immersion heater If the HPD is used to control more than one heater the POLARIS fitted with an HPD probe must be mounted slightly higher than the others Plug the probe lead into t...

Страница 13: ...ng add a small amount of common salt to increase the conductivity of the solution It is recommended that the probe assemblies are cleaned as part of the regular maintenance schedule to avoid build up...

Отзывы: