IMPORTANT
: Fire sprinkler heads must be located at an appropriate distance from the heater. This distance may
exceed the published clearance to combustibles. Certain applications will require the use of high temperature
sprinkler heads or relocation of heaters.
Potentially flammable substances, such as Propylene Glycol or antifreeze solutions, are not to be used in
conjunction with this heater.
For further information consult CAN/CSA B149.1 and 2. Always observe applicable provincial and local codes.
1.0 Safety • Gas Connection
An approved connector, suitable for the environment of equipment usage, is required. Visible or excessive swaying, flexing
and vibration of the gas connection must be avoided to prevent failure. Neither the gas pipe nor the connector shall be
placed in the flue discharge area or in direct contact with the infra-red rays. In no case shall the gas supply support or bear
the weight of the heater.
Brant Radiant Heaters Limited’s products comply or are certified by one or more of the following organizations or
standards:
• CSA International Requirement (CSA 2.37/5.90 U.S.)
Gas Connection
WARNING!
6