10
Electrical connections
Your hob is delivered with a three-
CROSS SECTION OF THE CABLE
TO USE conductor (phase +
neutral) H05WF- T105 or H05V2V2F -
T90 1mm2 section cable, which must be
connected to a 220-240 V~ single phase
mains supply by the intermediary of a two
phase + earth CEI 60083 standardized
neutral plug, or a single pole cut-off
device with a contact opening by at least
3,5mm.
The mains plug must be accessible after
installation.
The safety wire (green/yellow) is connected to the ground terminal of the
appliance and must be connected to the ground terminal of the installation.
The fuse in your set-up must be 5 amperes. If the power cable is damaged, it must
be replaced by a cable or a special kit available from the manufacturer or his After-
Sales Service.
C
ROSS
SECTION
OF
CABLE
TO
BE
USED
220-240 V~ - 50 HZ
Câble H05V2V2F - T90
3 conductors
including 1 ground
Cross section of
conductors in mm
2
1
Fuse
5A
Neutral
(N)
Live
(L)
Ground
Blue wire
H05V2V2F
cable
Black, brown
or red wire
Green/yellow
wire
Connect the wires to the electricity supply
making sure that the different-coloured
wires are in the right order.