ter Alarm
ity
4.
Error in the parity check in serial communication. If
this alarm occurs, check the transmission parameters for
both the printer and the computer, and also possibly the
software in use.
m
q
es
5.
Some irregularities have been detected when receiving
escape-sequences. If this alarm occurs, check the trans-
mission parameters for both the printer and the computer,
and also possibly the software in use. If the escape-
sequences are sent by a batch-fi le or are integrated in the
text-fi le, be sure that the correct ASCII-value combina-
tions are used.
On error messages, the printer cannot be operated, and RESET PRINTER must be used.
Printer
Error
General Failure
1.
If the main motor starts, but for some reason stops, this
message appears in the display, together with the audio
alarm. The reason migth be:
nter Error
rt Motor
2.
If the main motor does not start, this error message is
shown in the display. The reason might be:
Bad connection in the motor wires or a problem
inside the electrical unit (frequency converter).
A.
The belt on the printer breaks during printing.
Check the belt, and replace if needed.
B.
The main motor is not connected.
Check that the cable to the motor is connected.
A.
The belt is broken or out of place.
B.
System error.
D.
nter Error
Stop Motor
3.
The main motor does not stop. The reason might be:
Defect electrical unit.
A.
System error.
B.
Defect frequency converter.
C.
The main sensor might be defect, or have loose
connector.
C.
However, if the main motor does start, but this message
is still appearing in the display, it could be caused by
a defect main sensor, or a loose connector on the main
sensor.
BRAILLO
●
NORWAY AS
B 400 Series 3
26
Содержание 400 S 3 Series
Страница 1: ...User s Guide BRAILLO NORWAY BRAILLO 400 S Series 3 Rev September 2005...
Страница 2: ...September 2005 2005 Braillo Norway AS...
Страница 76: ...Frame exploded view BRAILLO NORWAY AS B 400 Series 3 76...
Страница 77: ...BRAILLO NORWAY AS B 400 Series 3 77 Paper guides...
Страница 80: ...Electric unit schematics BRAILLO NORWAY AS B 400 Series 3 80...