Copyright by Brähler ICS
13
4.5 Connecting radiator sockets
BNC 1 and BNC 2: BNC sockets for connecting INFRACOM® radiators
IRad. Up to 10 radiators can be connected directly to each socket.
Caution
: When wiring the radiators in band IV you must be aware of the following: Due to
the higher carrier frequencies the BNC cables to the radiators must have the same
length. Using two radiators in a row, the highest distance should not be greater than a
meter. Otherwise, there will be overlaps or extermination. Please note the application
examples in the corresponding chapter.
If there are more radiators needed we recommend the use of an active distributor SV/BNC. Our
planning department will be glad to help you.
4.6 Connecting A36 sockets
Two sockets A36 are provided for the connection to the interpreter consoles (i.e. DOL7/2). About
seven units may be connected directly to the transmitter. The total number depends on cable
length. If you have any questions don’t hesitate to ask. Our planning department will be glad to
help you.
4.7 Connecting mains power
Connect the delivered cable with this socket to ensure
the proper working of the Compact Transmitter.