background image

EM HEAT

          

R

         Y1
         Y2

  W1/E/AX1

        W2/AX2

O/B/W3

          G

          L

          C

THERMOST

AT

           

 

Z

ONE 

1

      

PO

COMM

      PC

DAMPER

ZONE 

1

          

R

         Y1
         Y2

  W1/E/AX1

        W2/AX2

O/B/W3

          G

          L

          C

THERMOS

TAT

          

 

Z

ONE 

2

DAMPER

ZONE 

2

      

PO

COMM

      PC

          

R

         Y1
         Y2

  W1/E/AX1

        W2/AX2

O/B/W3

          G

          L

          C

THERMOST

AT

          

 

Z

ONE 

3

      

PO

COMM

      PC

DAMPER

ZONE 

3

 

24V

 24C

POWER 24 

VA

C

EXP

ANSION

COM1
COM2
GND
COM3
COM4

EXP

ANSION

COM1
COM2
GND
COM3
COM4

R
Y1
Y2
W1/E/AX1
W2/AX2 
O/B/W3
G
L
C

THERMOS

TAT

       

 

 Z

ONE 

4

PO

COMM
PC

DAMPER

ZONE 

4

Rh
Rc
Y1
Y2
G
G2
W1/E/AX1
W2/AX2
W3/O/B
L
C

 

EQUIPMENT

FA1
FA2

FIRE

ALARM

SENSORS

SA1
SA2

ODT1
ODT2

SENSORS

 

             Terminal      Qty.     Function     Description

 

PANEL 

24V 

INPUT 

24 VAC Transformer Power 100 VA Maximum 

  POWER 

24C 

INPUT 

24 VAC Transformer Common

  DAMPERS 

PO       

OUTPUT 

24 VAC Power Open Zone Damper Terminal

   

COMM    

OUTPUT 

Zone Damper Common Terminal

   

PC       

OUTPUT 

24 VAC Power Close Zone Damper Terminal

  SUPPLY 

SA1 

INPUT 

Plenum Supply Air Sensor Terminal 1 (No Polarity)

  AIR 

SA2 

INPUT 

Plenum Supply Air Sensor Terminal 2 (No Polarity)

  OUTDOOR 

ODT1 

INPUT 

Outdoor Air Sensor Terminal 1 (No Polarity)

  AIR 

ODT2 

INPUT 

Outdoor Air Sensor Terminal 2 (No Polarity)

  FIRE 

FA1 

INPUT 

Normally Closed or Open Dry Pair (No Polarity)

  ALARM 

FA2 

INPUT 

Normally Closed or Open Dry Pair (No Polarity)

  EXPANSION 

COM1     

PANEL 

Expander Panel Communication

   

COM2    

PANEL 

Expander Panel Communication

   

GND   

PANEL 

Expander Panel Communication Ground

   

COM3     

PANEL 

Expander Panel Communication

   

COM4    

PANEL 

Expander Panel Communication

  EQUIPMENT 

Rh 

INPUT 

24 VAC Equipment Transformer Power Connection

  

Rc 

INPUT 

24 VAC Cooling Equipment Transformer (Dual Transformer Systems Only)

   

Y1 

OUTPUT 

1st Stage Compressor

   

Y2 

OUTPUT 

2nd Stage Compressor

   

OUTPUT 

1st Stage Fan Control

   

G2 

OUTPUT 

2nd Stage Fan Control

  

W1/E/AX1 

OUTPUT 

[W1] 1st Stage Conventional Heat [E] Emergency Heat [AX1] 1st Stage Auxiliary Heat

   

W2/AX2 

OUTPUT 

[W2] 2nd Stage Conventional Heat [AX2] 2nd Stage Auxiliary Heat

   

W3/O/B 

OUTPUT 

[W3] 3rd Stage Conventional Heat [O] Cool Active Reversing Valve 

   

 

 

 

[B] Heat Active Reversing Valve

   

INPUT 

System Malfunction Indicator

   

INPUT 

24 VAC Transformer Common

  THERMOSTAT 

R      

OUTPUT 

24 VAC Thermostat Power

   

Y1    

INPUT 

1st Stage Compressor Call

   

Y2    

INPUT 

2nd Stage Compressor Call

   

W1/E/AX1  

INPUT 

[W1] 1st Stage Conventional Heat Call [E] Emergency Heat Call 

   

 

 

 

[AX1] 1st Stage Auxiliary Heat Call

   

W2/AX2     

INPUT 

[W2] 2nd Stage Conventional Heat Call [AX2] 2nd Stage Auxiliary Heat Call

   

O/B/W3     

INPUT 

[O] Cool Active Reversing Valve Call [B] Heat Active Reversing Valve Call

   

 

 

 

[W3] 3rd Stage Conventional Heat Call

   

G     

INPUT 

Fan Call

   

L      

OUTPUT 

System Malfunction Indicator

   

C      

OUTPUT 

24 VAC Transformer Common

   

RESET BUTTON   

 

Press once to restart panel

   

 

 

 

Hold for 5 seconds to reset panel and restore all factory defaults

   

Rc/Rh TERMINAL JUMPER (J1) 

Open jumper for dual transformer installations

   

WIRE STRIP GUIDE 

 

Wires should be stripped 3/8 inch minimum

  

 

EXPANDABLE ZONE PANEL WIRING TERMINALS

5

1

2

3

4

5

6

7

8

9

10

11

Содержание 140404

Страница 1: ...he entire panel before applying transformer power This panel is designed for professional installation and is to be installed and configured as described in this manual Any other use is not recommende...

Страница 2: ...lectronic self resetting current limiting for panel power and damper zones Configuration Conventional and Heat Pump equipment up to 4 Heating Stages and 2 Cooling Stages Maximum Zones 4 Zones Main Pan...

Страница 3: ...aster installations Figure 2 3 EM HEAT R Y1 Y2 W1 E AX1 W2 AX2 O B W3 G L C T HERMOSTAT Z ONE 1 PO COMM PC DAMPER ZONE 1 R Y1 Y2 W1 E AX1 W2 AX2 O B W3 G L C T HERMOSTAT Z ONE 2 DAMPER ZONE 2 PO COMM...

Страница 4: ...op of wiring terminal and gently pull out wire s EM HEAT R Y1 Y2 W1 E AX1 W2 AX2 O B W3 G L C T HERMOSTAT Z ONE 1 PO COMM PC DAMPER ZONE 1 R Y1 Y2 W1 E AX1 W2 AX2 O B W3 G L C T HERMOSTAT Z ONE 2 DAMP...

Страница 5: ...PUT 2nd Stage Compressor G 1 OUTPUT 1st Stage Fan Control G2 1 OUTPUT 2nd Stage Fan Control W1 E AX1 1 OUTPUT W1 1st Stage Conventional Heat E Emergency Heat AX1 1st Stage Auxiliary Heat W2 AX2 1 OUTP...

Страница 6: ...ne Panel 2 Wire Damper PO C PC PO COM PC Zone Panel 3 Wire Damper Thermostat Wiring 3 2 Install the system thermostats using the instructions provided by the manufacturer Connect the thermostats to th...

Страница 7: ...eat Call G Fan Call C 24 VAC Transformer Common Note 1 3 HEAT 2 COOL With Auxiliary Heat R 24 VAC Power O B Changeover Valve Note 2 L Optional System Fault Monitor AX1 Auxiliary Heat Relay 3rd Stage H...

Страница 8: ...panel as shown For a single stage heating and cooling system the 2nd and 3rd stage connections are not used For a system using a dual transformer remove jumper Rc to Rh see Figure 3 page 4 Make sure...

Страница 9: ...Power Heating Transformer Rc Connected to Rh with Jumper O B Changeover Valve Note 4 L Optional System Fault Monitor W2 Auxiliary Heat Relay 2nd Stage Heating Note 5 Y1 Compressor Call Stage 1 1st St...

Страница 10: ...ms you will need to make configuration changes described in this section To start configuration 1 Press SETUP and hold for 3 seconds 10 2 The panel backlight will turn on and the display will change 3...

Страница 11: ...trol REV VAL O O Select for cool active reversing valve B Select for heat active reversing valve Note 7 6 Auxiliary Stage COMP LOC OFF OFF Select for Compressor runs with Auxiliary Heat Call Compresso...

Страница 12: ...ted 17 Second Stage Fan G2 ZONES 2 2 of Select the number of zones that must call before the zones second stage fan will turn on 18 Priority Zone PRIORTY 1 OFF Select to have opposite calls answered i...

Страница 13: ...municating properly the display will show the zone number and OK If the zone is not communicating properly the display will show Address Invalid or Duplicate Address See Error Conditions section 7 for...

Страница 14: ...PC This test powers all dampers open or closed Press SELECT to test or NEXT to advance to return to first test LED COLOR INDICATION Panel Status LED Panel Power Green Flashing Green When Normal Equip...

Страница 15: ...D s the expandable zone panel has a full function built in backlit display panel that provides information on the current operations of the zone panel When the expandable zone panel is running in norm...

Страница 16: ...o cooling calls will be answered if emergency heat is switched on To select Emergency Heat from the main panel 1 Press and release the EM HEAT button located below the main display 2 The display will...

Страница 17: ...un Delay HI Limit Displayed when the Plenum Temperature is exceeded during equipment heating operation All heating stages will be turned off and the fan will be turned on until the plenum temperature...

Страница 18: ...an expansion panel This message will appear when an expander is powered up and wired to the communication terminals To locate the expander panel with the invalid address view the expander panel status...

Страница 19: ...anel display 4 If new zones do not appear check wiring and ensure expansion zones have power 5 Press HOLD FOR EXIT for 3 seconds to complete adding zones The expansion zones may be wired to either the...

Страница 20: ...es 5 6 Expander Panel Zones 7 8 Expander Panel As Needed Daisy Chain All Zones Located at Main Panel Star Wiring All Zones Located at Main Panel Main Panel Expander Panel Zones 7 8 Expander Panel Zone...

Страница 21: ...Panel Zones 7 8 500 Ft Maximum 21 Main Panel Expander Panel Zones 5 6 Expander Panel As Needed 500 Ft Maximum Expander Panel As Needed Expander Panel As Needed Daisy Chain Zones Located Remote to Mai...

Страница 22: ...opy of this warranty Visit us online www braeburnonline com warranty Phone us 866 268 5599 Write us Braeburn Systems LLC 2215 Cornell Avenue Montgomery IL 60538 5YEAR WARRANTY LIMITED Braeburn Systems...

Отзывы: