Cleaning and Maintenance Instructions for Terreon®

Material Description: Terreon

® 

is a NAHB Certified densified solid surface material composed of polyester

resin and is resistant to chemicals, stains, burns and impact. Surface damage can be easily repaired with
everyday cleansers or fine grit abrasives.

Routine Cleaning: Clean daily or as often as conditions require using a standard commercial or household
cleaner such as Formula 409

®

or Windex

®

.

Stubborn Stains: Remove tough stains with Ajax

®

, Comet

®

, or Soft-Scrub

®

and a green Scotch-Brite

®

pad or

lightly sand in a circular motion with 240 grit wet/dry sandpaper. The finish can be renewed with a maroon
Scotch-Brite pad.

Special Situations for Material

Scratches: Remove scratches with a green Scotch-Brite

®

pad. The finish can then be renewed with a maroon

Scotch-Brite

®

pad.

Hard Water Deposits: Remove hard water deposits with a mild solution of vinegar and water. Always rinse
the unit thoroughly after cleaning.
Restoring the surface: Use Hope's

®

Solid Surface cleaner and polish to refresh and protect the Terreon

Solid Surface material.Bradley recommends additional care and maintenance for the darker colored Terreon,
for complete instructions on this additional maintenance see Bradley document #1505.

IMPORTANT:

DO NOT USE STRONG ACID OR ALKALINE CHEMICALS AND
CLEANSERS TO CLEAN TERREON. IF THESE CHEMICALS COME IN
CONTACT WITH THE TERREON SURFACE, WIPE THEM OFF
IMMEDIATELY AND RINSE WITH SOAPY WATER.

AVOID CONTACT WITH HARSH CHEMICALS SUCH AS PAINT REMOVER,
BLEACH, ACETONE, ETC. AVOID CONTACT WITH HOT PANS AND
OBJECTS.

Repair Kits: Terreon

®

repair kits are available. Contact your Bradley representative or distributor for part

numbers and pricing.

NOTE: Repair kits are made to order and have a shelf life of 30 days.

Brand Names: Use of brand names is intended only to indicate a type of cleaner. This does not constitute an
endorsement, or does the omission of any brand name cleaner imply it’s inadequacy. Many products named are
regional in distribution, and can be found in local supermarkets, department and hardware stores, or through
your cleaning service. It is emphasized that all products should be used in strict accordance with package
instructions.

NOTE: When cleaning units equipped with infrared (electronic eye) activation, it is helpful to turn off
the power to the unit or cover the windows to prevent accidental activation. After the window is
covered, the water will run for approximately 30 seconds and then shut off.

Содержание Terreon Quadra-Fount Washfountain MF2944/TT

Страница 1: ...on Page 1 of 16 12 18 2003 P O Box 309 Menomonee Falls WI 53052 0309 TEL 1 800 BRADLEY FAX 262 251 5817 http www bradleycorp com IMPORTANT Read through this installation manual to ensure proper installation Make sure that water supply is completely off before installation is begun When drilling into tile masonry or other hard materials to install wall and floor anchors be sure to wear safety goggl...

Страница 2: ...n Warranty Information Bradley Corporation warrants to commercial and institutional purchasers only each unit free from defects in material and workmanship under normal use and service upon the following terms and conditions 1 This warranty is limited to replacing or repairing at our option transportation charges prepaid by the purchaser any Bradley unit or part thereof which our inspection shall ...

Страница 3: ... any parts are missing do not attempt to assemble the Quadra Fount until you obtain all parts Supplies required 6 3 8 diameter bolts with washers and 6 wall anchors appropriate for your installation 2 3 8 diameter bolts with washers and 2 floor anchors appropriate for your installation 1 2 NPT Hot and cold water supply lines Drain trap and waste connection Pipe sealant and plumber s putty 110 VAC ...

Страница 4: ...ng rough in dimensions and wall anchor locations IMPORTANT Make sure that the water is completely shut off before beginning installation 1 Rough in hot and cold supply lines through the wall or floor 2 Rough in a drain waste connection through the wall or floor IMPORTANT Wall anchors need to withstand 1000 lb pull force 7 178 5 1 8 130 2 51 11 279 11 279 17 1 2 445 24 610 21 3 4 552 28 711 7 1 2 1...

Страница 5: ...s are not utilized on back of mounting panel Refer to Figure 2 when assembling pedestal 1 Fasten the mounting panel to the pedestal with four pan head 1 4 20 x 1 2 screws supplied 2 Install the upper bracket to the pedestal panels with two pan head 1 4 20 x 1 2 screws and 5 16 I D washers supplied 3 Install the lower bracket to the pedestal panels with two pan head 1 4 20 x 1 2 screws and 5 16 I D...

Страница 6: ... you move the pedestal assembly to the wall using appropriate lifting procedures and align the locating notches on the mounting panel with the centerline marked on the wall If the floor is not level install shims under the left and or right pedestal NOTE Remove molding strips or tiles which could prevent mounting unit flush to the wall 3 Drill holes in the wall through the four 1 2 diameter holes ...

Страница 7: ...e bracket to the left side of the pedestal as shown IMPORTANT The hose attached to the hot water inlet of the Navigator TMV valve marked with H must be connected to the hot water rough in 5 Connect the supply hoses to the Navigator TMV valve 6 FOR OPTIONAL SINGLE TEMPERED SUPPLY Attach the stop check valve to the 1 2 tempered supply line Connect the stop check valve to the solenoid valve with the ...

Страница 8: ... x 2 hex head bolts 13 32 I D plain washers anchor plates lockwashers and hex nuts provided as shown in Figure 5 5 Uncoil the Touch Time switch leads and plastic tubing from the rear of the backsplash 6 Slide the bowl back to the wall and secure the bowl s wall brackets to the wall anchors with two 3 8 diameter bolts and washers supplied by installer 7 Fasten the bowl to the upper bracket on the p...

Страница 9: ...es and ordinance is the responsibility of the installer 1 Connect the wires per the wiring diagram shown below 2 Insert four different colored sprayhead supply tubes into four solenoid tube connectors as shown in Figure 7 by loosening tube connector cap and firmly pushing tubing into tube connector until the tubes are fully seated then re tighten connector cap Supply Inlet Navigator Mixing Valve S...

Страница 10: ...ximately 1 0 GPM water flow is reached and adjust if necessary the range of the valve is 95 F 115 F 35 C 43 C To adjust the temperature follow the procedure below Loosen temperature locking nut with wrench Using a blade screwdriver turn the adjustment stem counterclockwise to increase the temperature or clockwise to decrease the temperature Figure 8 Once desired temperature is reached tighten nut ...

Страница 11: ...n Solid Surface material Bradley recommends additional care and maintenance for the darker colored Terreon for complete instructions on this additional maintenance see Bradley document 1505 IMPORTANT DO NOT USE STRONG ACID OR ALKALINE CHEMICALS AND CLEANSERS TO CLEAN TERREON IF THESE CHEMICALS COME IN CONTACT WITH THE TERREON SURFACE WIPE THEM OFF IMMEDIATELY AND RINSE WITH SOAPY WATER AVOID CONTA...

Страница 12: ...factures instructions Many of these products leave a protective coating the helps prevent future smears and fingerprints Grease and Oil To remove grease and oil use a quality commercial detergent or caustic cleaner Apply in accordance to the manufactures instructions and in the direction of the polish lines Precautions Avoid prolonged contact with chlorides bleaches salts bromides sanitizing agent...

Страница 13: ...u may crack the plastic valve body Tighten until the armature plate makes contact with the plastic body 4 Reconnect the wiring per diagram on page 9 Problem An individual operating station fails to turn on Cause A failed coil for the valve or loose electrical connection to the terminal Solution Test the station to determine cause 1 Disconnect the wires from the coil of an adjacent valve Disconnect...

Страница 14: ...S07 068A thru body 1 2 3 4 5 6 7 8 9 8 DESCRIPTION QTY PART NO REF 1 1 118 307 VALVE BODY 1 4 CLOSED 2 1 269 983 DIAPHRAGM 3 1 269 577 ARMATURE 4 1 269 578 SPRING 5 1 269 1729 ARMATURE HOUSING 6 1 269 1730 CLAMP ARMATURE HOUSING 7 1 269 579 COIL SOLENOID VALVE 8 3 160 447 SCREW 8 X 5 8 9 1 125 001CS O RING 2 013 10 10 1 125 160 FLOW RESTRICTOR 5 GPM 1 1 118 307A VALVE BODY 1 4 THRU Figure 11 ...

Страница 15: ...ng the piston and valve body Remove the thermostat Lift the piston out with a needle nose pliers and remove the spring Any cleaner suitable for brass and stainless steel may be used if cleaning with suitable cleaner is not sufficient to remove debris a 400 grit sandpaper may be used to polish and hone the piston and valve body Snap spring into piston will detent and reassemble into the valve body ...

Страница 16: ...39 Rev A EN 03 063 16 12 18 2003 6 5 4 3 2 1 10 10 7 Strainer Strainer Valve Body Spring Thermostat Piston Stem O Ring O Ring 2 1 Spring 3 1 Piston 4 1 Thermostat 6 1 O Ring 7 1 O Ring Item Qty Description 173 028 Strainer Repair Kit S65 259 9 8 Cap Nut 3 8 24 Hex Jam Figure 12 Navigator Thermostatic Mixing Valve S01 520 ...

Отзывы: