Terreon® Quadra-Fount® Washfountain with Touch Time® Control
MF2944/TT
Installation Instructions
Bradley Corporation • 215-1539 Rev. A; EN 03-063
4
12-18-2003
Installation Instructions
Step 1: Install the 24 VAC transformer
CAUTION: The Quadra-Fount® must be connected with a 24 VAC Class II plug-in
transformer. Connection with 110 VAC will result in damage to the
electronics and could result in personal injury.
IMPORTANT: Consult local electrical codes for the mounting location of the 110/24
VAC Class II plug-in transformer.
IMPORTANT: Compliance and conformity to local codes and ordinances is the
responsibility of the installer.
Step 2: Rough-in piping and install wall anchors
NOTE: See Figure 1 for piping rough-in dimensions and wall anchor locations.
IMPORTANT: Make sure that the water is completely shut off before beginning
installation.
1. Rough-in hot and cold supply lines through the wall or floor.
2. Rough-in a drain waste connection through the wall or floor.
IMPORTANT: Wall anchors need to withstand 1000 lb. pull force.
7"
(178)
5-1/8" *
(130)
2"
(51)
11"
(279)
11"
(279)
17-1/2" *
(445)
24" *
(610)
21-3/4"
(552)
28" *
(711)
7-1/2"
(191)
7"
(178)
8"
(203)
110V GFI ELECTRICAL
OUTLET RECOMMENDED
LOCATION (REFER TO LOCAL
CODES BEFORE ROUGH-IN)
FINISHED FLOOR
1-1/2" NPT WASTE CONNECTION
THROUGH FLOOR - 3" FROM WALL
1/2 NPT SUPPLIES - 5" FROM WALL
STUB OUT MIN. 1-1/2"
FROM FLOOR
1/2 NPT SUPPLIES
STUB OUT MIN. 1-1/2"
FROM WALL
1-1/2 NPT WASTE CONNECTION
FOR USE WITH 1-1/2" TUBULAR P-TRAP
STUB OUT MIN. 1-1/2"
(2) APPROPRIATE ANCHORS
AND 3/8" BOLTS (SUPPLIED
BY INSTALLER TO MOUNT
BOWL TO WALL
Figure 1
* Subtract 4" from this dimension for juvenile height model.