Express® Deck Lavatory System EXD Series
Installation Instructions - For Service Only
EXD-3/WH97
3
Bradley Corporation •
215-1278 Rev. C; EN 03-817
6/8/04
Installation Instructions
Supplies required for installation:
• (10) 3/8" wall anchors, bolts and washers to mount frame and bowl to wall (minimum pull-out
rating of 1,000 lbs.)
• 1/2" NPT tempered supply piping
• 1-1/2" NPT drain piping
• 110 volt electrical outlet for optional 110/24 VAC plug-in transformer for infrared faucet option
Step 1: Rough in
IMPORTANT: Dimensions in Figure 1a are for a Standard Height Express® Deck
only. See Figure 1b on page 4 for Juvenile Height Express® Deck.
1. Rough in 1/2" NPT hot and cold supply lines through wall at dimensions shown.
2. Rough in 1-1/2" NPT drain waste connection through wall at dimensions shown.
3. Install ten 3/8" wall anchors with a minimum pull-out rating of 1,000 lbs. (supplied by installer)
at the locations shown in Figure 1a below or Figure 1b on page 4.
4. INFRARED FAUCET OPTION ONLY: Install the 110 volt GFCI electrical outlet per local code
at the location shown in Figure 1a below or 1b on page 4.
Figure 1a
Standard Height Mounting - EXD-3/WH97