Installation Instructions

Supplies required for installation:

• (10) 3/8" wall anchors, bolts and washers to mount frame and bowl to wall (minimum pull-out

rating of 1,000 lbs.) 

• 1/2" NPT tempered supply piping
• 1-1/2" NPT drain piping
• 110 volt electrical outlet for optional 110/24 VAC plug-in transformer for infrared faucet option

Step 1: Rough in

IMPORTANT:  Dimensions in Figure 1a are for a Standard Height Express® Deck

only. See Figure 1b on page 4 for Juvenile Height Express® Deck.

1. Rough in 1/2" NPT hot and cold supply lines through wall at dimensions shown.

2. Rough in 1-1/2" NPT drain waste connection through wall at dimensions shown.

3. Install ten 3/8" wall anchors with a minimum pull-out rating of 1,000 lbs. (supplied by installer)

at the locations shown in Figure 1a below or Figure 1b on page 4.

4. INFRARED FAUCET OPTION ONLY: Install the 110 volt GFCI electrical outlet per local code

at the location shown in Figure 1a below or 1b on page 4.

Figure 1a

Standard Height Mounting - EXD-3/WH97

Содержание Express EXD Series

Страница 1: ...making connections Debris in supply lines will cause the valves to malfunction Turn OFF electrical power to the outlet when installing the Express Deck Wall anchors used must have a minimum pull out r...

Страница 2: ...ess Deck Lavatory System EXD Series EXD 3 WH97 Installation Instructions For Service Only 2 6 8 04 Bradley Corporation 215 1278 Rev C EN 03 817 EXD 3 WH97 Express Deck Dimensions Standard Height Mount...

Страница 3: ...ion Step 1 Rough in IMPORTANT Dimensions in Figure 1a are for a Standard Height Express Deck only See Figure 1b on page 4 for Juvenile Height Express Deck 1 Rough in 1 2 NPT hot and cold supply lines...

Страница 4: ...xpress Deck Lavatory System EXD Series EXD 3 WH97 Installation Instructions For Service Only 4 6 8 04 Bradley Corporation 215 1278 Rev C EN 03 817 Figure 2 Figure 1b Juvenile Height Mounting EXD 3 WH9...

Страница 5: ...el IMPORTANT Anchoring the frame to a wall that is not flat may cause the frame to bend If necessary install shims to compensate for any wall distortion 3 Ensure that the back of the frame is flat aga...

Страница 6: ...e the bowl assembly squarely onto the frame 2 Attach the front of the bowl assembly to the frame using the four 1 4 20 x 3 8 pan head screws and washers provided Do not tighten screws at this time IMP...

Страница 7: ...2 tempered supply line Connect the stop check strainer to the solenoid valves with the flexible supply hose see Figure 5b 2 Install the two drain plugs in the two holes in the bottom of the bowl see...

Страница 8: ...amp cloth and a household liquid detergent Stubborn stains can be removed as follows 1 Using a 7448 Scotch Brite pad scrub with an abrasive cleanser such as Ajax Comet or Soft Scrub and water 2 Clean...

Страница 9: ...Frame and Panel Assembly of Components STOP STRAINER CHECK VALVE S60 003 90 ELBOW 169 639 BRASS PIPE NIPPLE 113 006DJ 7 5 8 194mm 1 2 14 NPT SUPPLIED BY INSTALLER THERMOSTATIC MIXING VALVE S01 116 CO...

Страница 10: ...replace with a new ring NOTE An old or worn flip ring may cause temperature fluctuation and or water chatter 3 Reassemble the power element and valve body Apply grease to the main valve slide and gen...

Отзывы: