Figure 4

Installation Instructions

continued . . . 

Step 3: Installing bowl assembly

NOTE:  Refer to Figure 4 below when installing the bowl assembly.

IMPORTANT:  Moving and positioning the bowl requires more than one person.

1. With someone to assist you, place the bowl assembly squarely onto the frame.

2. Attach the front of the bowl assembly to the frame using the four 1/4"-20 x 3/8" pan-head screws

and washers provided. 

Do not tighten screws at this time.

IMPORTANT:  When bolting the bowl assembly to the frame and wall, do not

overtighten bolts. Overtightening bolts can damage the Terreon®
material.

3. After the bowl assembly is attached to the frame, use two 3/8" bolts and washers (supplied by

the installer) to bolt the bowl to the wall anchors.

4. Tighten the screws installed in procedure #2 above to secure the bowl assembly to the frame. 

Do

not overtighten.

Содержание Express EXD Series

Страница 1: ...making connections Debris in supply lines will cause the valves to malfunction Turn OFF electrical power to the outlet when installing the Express Deck Wall anchors used must have a minimum pull out r...

Страница 2: ...ess Deck Lavatory System EXD Series EXD 3 WH97 Installation Instructions For Service Only 2 6 8 04 Bradley Corporation 215 1278 Rev C EN 03 817 EXD 3 WH97 Express Deck Dimensions Standard Height Mount...

Страница 3: ...ion Step 1 Rough in IMPORTANT Dimensions in Figure 1a are for a Standard Height Express Deck only See Figure 1b on page 4 for Juvenile Height Express Deck 1 Rough in 1 2 NPT hot and cold supply lines...

Страница 4: ...xpress Deck Lavatory System EXD Series EXD 3 WH97 Installation Instructions For Service Only 4 6 8 04 Bradley Corporation 215 1278 Rev C EN 03 817 Figure 2 Figure 1b Juvenile Height Mounting EXD 3 WH9...

Страница 5: ...el IMPORTANT Anchoring the frame to a wall that is not flat may cause the frame to bend If necessary install shims to compensate for any wall distortion 3 Ensure that the back of the frame is flat aga...

Страница 6: ...e the bowl assembly squarely onto the frame 2 Attach the front of the bowl assembly to the frame using the four 1 4 20 x 3 8 pan head screws and washers provided Do not tighten screws at this time IMP...

Страница 7: ...2 tempered supply line Connect the stop check strainer to the solenoid valves with the flexible supply hose see Figure 5b 2 Install the two drain plugs in the two holes in the bottom of the bowl see...

Страница 8: ...amp cloth and a household liquid detergent Stubborn stains can be removed as follows 1 Using a 7448 Scotch Brite pad scrub with an abrasive cleanser such as Ajax Comet or Soft Scrub and water 2 Clean...

Страница 9: ...Frame and Panel Assembly of Components STOP STRAINER CHECK VALVE S60 003 90 ELBOW 169 639 BRASS PIPE NIPPLE 113 006DJ 7 5 8 194mm 1 2 14 NPT SUPPLIED BY INSTALLER THERMOSTATIC MIXING VALVE S01 116 CO...

Страница 10: ...replace with a new ring NOTE An old or worn flip ring may cause temperature fluctuation and or water chatter 3 Reassemble the power element and valve body Apply grease to the main valve slide and gen...