DV Series
27
Honeywell Valve Body Removal and Temperature Sensor Removal
Unclip lower right
side first
Unclip lower left
side second
Valve body screw
Step 1. Disconnect the burner and pilot tubes per Service Procedure II.
Step 2. Remove the valve body by removing the screw located at the lower
left corner. Unclip the lower right side from the backplate first,
followed by the lower left side, using a flat-head screwdriver.
Step 3. Remove the temperature sensor and insertion stick from the backplate by first removing
the wire from the temperature sensor wire routing clips. Make note of the insertion stick’s
orientation, as the insertion stick can only be installed in one way.
CAUTION
Use caution to not
bend or damage
valve body pins.
CAUTION
When reinstalling
temperature sensor and
insertion stick, make sure
the assembly is inserted
FULLY into the backplate
and the wires are routed
through the wire routing
clips. Failure to do so will
not allow the valve body to
be reinstalled properly and
may damage temperature
sensor wires.
Temperature sensor
wire routing clips
Insertion stick fully
inserted into backplate
Service Procedure IV
Gas Control Testing and
Replacement (Honeywell ONLY)
27