6
SECTION II: SPECIFICATIONS
Table 1.
Specifications
.
Model
TGHE-160I-N(X) TGHE-199I-N(X)
Minimum Rate Btu/h
9,500 (Natural) / 10,300 (Propane)
Maximum Rate Btu/h
157,000
199,000
Flow Rate (Min-Max) *
0.4-8.0 GPM (1.5-30 L/min)
0.4-9.8 GPM (1.5-37 L/min)
Flow Rate (45°F rise)
6.6 GPM (25 L/min)
8.5 GPM (32 L/min)
Default Temperature Setting
104°F (40°C)
Maximum Temp Setting
(commercial **)
185°F (85°C)
Maximum Temp Setting (residential)
Selectable at 120°F (49°C) or 140°F (60°C)
Minimum Temperature Setting
98°F (37°C)
Weight
64 lb (29 kg)
71 lb (32.2 kg)
Energy Factor
0.96
0.94
Thermal Efficiency
95%
Noise level (inside rating)
50 dB
Electrical
Consumption
Normal
63 W
80 W
Standby 2
W
Anti-frost Protection
220 W
220 W
By-Pass Control
Electronic
Minimum Gas
Supply
Pressure
Natural Gas
5.0 inch W.C.
Propane
8.0 inch W.C.
Maximum Gas
Supply
Pressure
Natural Gas
10.5 inch W.C.
Propane
13.5 inch W.C.
Type of Appliance
Condensing, Tankless, Direct Vent, Temperature controlled continuous flow gas
water heater
Operation
With or without remote controls, mounted in kitchen, bathroom, etc.
Approved Gas Type
Natural Gas or Propane - ensure unit matches gas type supplied at the installation
location.
Connections
Gas Supply: 3/4" MNPT, Cold Water Inlet: 3/4" MNPT, Hot Water Outlet: 3/4"
MNPT
Ignition System
Direct Spark Ignition
Electric Connections
Water Heater: AC 120 Volts, 60Hz. Remote Control: DC 12 Volts (Digital)
Water Temperature Control
Simulation Feedforward and Feedback
Minimum Water Supply Pressure
50 PSI (Recommended 60-80 PSI for maximum performance)
Maximum Water Supply Pressure
150 PSI
Remote Control Cable
Non-Polarized Two Core Cable (Minimum 22 AWG)
ENERGY STAR
®
Qualified
Yes
* Minimum flow may vary slightly depending on the temperature setting and the inlet water temperature.
** For commercial and hydronic applications requiring higher temperatures. Requires the use of an optional controller
(P/N 239-48789-00).
Bradford White Corporation is continually updating and improving products. Therefore, specifications are subject to
change without prior notice.
The maximum inlet gas pressure must not exceed the value specified by the manufacturer. The minimum value
listed is for the purpose of input adjustment.
Содержание EverHot TGHE-160I-N
Страница 16: ...16 Figure 4 Recommended Piping for a Basic Installation...
Страница 17: ...17 Figure 5 Recommended Piping for a Circulation Systems Pump to be of bronze or stainless construction...
Страница 27: ...27 Figure 10 Illustration Showing a Horizontal Termination Installation...
Страница 48: ...48 Figure 35 Wiring Diagram for TGHE Models...
Страница 68: ...68 SECTION X PARTS LIST TGHE 160I and TGHE 199I Models...
Страница 70: ...70...
Страница 72: ...72...
Страница 74: ...74...
Страница 79: ...79 NOTES...