TROUBLESHOOTING 

LED

 

Status

 

Control

 

Status

 

Probable

 

Cause

 

None

 

(LED

 

not

 

on

 

or

 

flashing)

 

Electrical

 

power

 

not

 

present.

 

Control

 

power

 

switch

 

in

 

“OFF”

 

position.Supply

 

voltage

 

interuppted.

 

One

 

short

 

flash

 

every

 

four

 

seconds

 

Stand

by

 

mode,

 

Thermostat

 

is

 

satisfied

 

(no

 

faults).

 

Temperature

 

demand

 

is

 

satisfied

 

(no

 

call

 

for

 

heat).

 

Alternates

 

bright

 

and

 

dim

 

(Heartbeat)

 

Thermostat

 

calling

 

for

 

heat

 

(no

 

fault).

 

Tank

 

temperature

 

below

 

set

 

point

 

of

 

thermostat.

 

Short

 

flash

 

once

 

every

 

second

 

Weak

 

pilot

 

signal

 

on

 

last

 

call

 

for

 

heat.

 

1.

 

Unstable

 

pilot.

 

2.

 

Pilot

 

tube

 

block

 

or

 

restricted.

 

3.

 

Oxidation

 

build

 

up

 

on

 

pilot

 

electrode.

 

4.

 

Wire

 

damage

 

to

 

pilot

 

assembly

 

or

 

bad

 

connection

 

at

 

gas

 

valve.

 

Short

 

flash

 

once

 

every

 

two

 

seconds

 

Idle

 

remote

 

command

 

off

 

1.

 

Control

 

put

 

in

 

idle

 

or

 

Sabbath

 

mode

 

from

 

accessory

 

module

 

Two

 

flashes,

 

three

 

second

 

pause

 

Pressure

 

switch

 

not

 

working

closed

 

position.

 

1.

 

Pressure

 

switch

 

tubing

 

kinked

 

or

 

blocked.

 

2.

 

Blocked

 

pressure

 

tap

 

on

 

switch.

 

3.

 

Faulty

 

pressure

 

switch.

 

Three

 

flashes,

 

three

 

second

 

pause

 

Pressure

 

switch

 

or

 

blower

 

temperature

 

switch

 

not

 

working

 ‐

open

 

position.

 

1.

 

Vent

 

blockage

 

or

 

improper

 

vent

 

configuration.

 

2.

 

Pressure

 

switch

 

tubing

 

kinked

 

or

 

blocked.

 

3.

 

Blower

 

not

 

spinning

 

up

 

to

 

speed.

 

4.

 

Vent

 

temperature

 

too

 

high

 

5.

 

Faulty

 

pressure

 

switch

 

or

 

vent

 

limit

 

switch.

 

Four

 

flashes,

 

three

 

second

 

pause

 

Excessive

 

tank

 

temperature.

 

System

 

must

 

be

 

reset.

 

1.

 

Excessive

 

sediment

 

2.

 

Hot

 

water

 

entering

 

the

 

tank

 

from

 

another

        

 

source

 

in

 

the

 

potable

 

loop.

 

3.

 

Faulty

 

gas

 

valve.

 

Five

 

flashes,

 

three

 

second

 

pause

 

False

 

pilot

 

flame

 

present.

 

1.

 

Pilot

 

valve

 

stuck

 

in

 

open

 

position.

 

Six

 

flashes

one

 

flash,

 

three

 

second

 

pause

 

(Soft

 

lockout)

 

Failed

 

to

 

light

 

pilot.

 

System

 

auto

 

resets

 

after

 

5

 

minutes.

 

1.

 

Unstable

 

pilot.

 

2.

 

Pilot

 

tube

 

blocked

 

or

 

restricted.

 

3.

 

Oxidation

 

build

 

up

 

on

 

pilot

 

electrode.

 

4.

 

Wire

 

damage

 

to

 

pilot

 

assembly

 

or

 

bad

 

connection

 

at

 

gas

 

valve.

 

Содержание 51000B

Страница 1: ...hone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas...

Страница 2: ...n the event of improper usage or storage of gasoline or other flammable materials in the location where the water heater is installed the technology will resist ignition of the flammable vapors outsid...

Страница 3: ...2 L 60 Gal 227 1 L 19 Vent Pipe Preparation and Joining 25 Combustion Air Supply 27 Water Connections 29 Gas Connections 32 Electrical Connections 33 Wiring Diagram 34 GENERAL OPERATION 35 Lighting an...

Страница 4: ...ranty Do not use this appliance if any external part to the tank has been submerged in water You should contact a qualified service technician to inspect the appliance and to replace any part of the c...

Страница 5: ...anada CAN CGA B149 1 Natural Gas Installation Code Latest Edition or CAN CGA B149 2 Propane Installation Code Latest Edition The location of this water heater is of the utmost importance Before instal...

Страница 6: ...R HEATER To comply with NSF requirements this water heater is to be a Sealed to the floor with sealant in a smooth and easily cleanable way or b Installed with an optional leg kit that includes legs a...

Страница 7: ...least 3 4 inch 1 9 cm in diameter and pitched for proper drainage It is recommended that a minimum clearance of four 4 inches 10 2 cm be provided on the side of the water heater for servicing and main...

Страница 8: ...earances to combustibles for this water heater are zero 0 inch 0 cm from the sides and rear five 5 inches 12 7 cm from the front of the jacket zero 0 inch 0 cm from the vent connector and fifteen 15 i...

Страница 9: ...t 2 13 m M Clearance under a veranda porch deck or balcony 12 inches 30 cm b 1 In accordance with the current CAN CGA B149 Installation Codes 2 In accordance with the current ANSI Z223 1 Latest editio...

Страница 10: ...installation instructions Venting system must not pass through rated fire separations The venting system must be free to expand and contract This venting system must be supported in accordance with t...

Страница 11: ...ing tables for approved venting materials primers and cements All approved primers and cements are to be used within their marked time limitations Approved Venting Materials For installations in the U...

Страница 12: ...structions for proper installation Part I Venting Specifications for 48 Gallon 181 6 L 65 Gallon 246 0 L This water heater is a power vented appliance and is designed to vent its products of combustio...

Страница 13: ...7 2 1 Through the Roof 3 45 13 7 7 2 1 TABLE 2 VENT CONNECTOR LENGTHS FOR 4 10 2 cm DIAMETER VENT PIPE Terminating of 90 Elbows excl vent term Maximum straight Length ft m Min straight Length ft m 48...

Страница 14: ...re the 90 vent terminal provided with the water heater to the vent connector The distance between the edges of the 90 vent terminal and the exterior wall see Figure 3 must be 1 in 2 5 cm Use the prope...

Страница 15: ...15 Venting Part I continued 4 VENT INSTALLATION 3 VENT INSTALLATION Figure 3...

Страница 16: ...local codes and or The National Fuel Gas Code ANSI Z223 1 Latest Edition or CGA CAN B149 Installation Code latest edition Figure 4 NOTE For installations requiring both horizontal and vertical runs th...

Страница 17: ...height greater than or equal to 12 30 5 cm above the ground or anticipated snow level the installation must be modified as shown below see Figure 5 Refer to Table 3 for maximum venting lengths using...

Страница 18: ...ALLATIONS Terminating Reduce 4 to 3 Reduce 10 1 cm to 7 6 cm of Elbows Max straight Length ft m Min straight Length ft m 48 65 gal 2 90 Elbows with 1 90 Elbow 1 160 48 8 10 3 1 2 90 Elbows with 1 90 E...

Страница 19: ...e venting distances allowed with 3 7 6 cm diameter vent pipe When venting with 3 7 6 cm vent pipe use a 3 7 6 cm to 2 5 1 cm reducer to exit through the building wall with 2 5 1 cm vent pipe Use the 2...

Страница 20: ...l 5 95 29 0 10 3 1 Through the Roof 0 120 36 6 15 4 6 Through the Roof 1 115 35 15 4 6 Through the Roof 2 110 33 5 15 4 6 Through the Roof 3 105 32 0 15 4 6 Through the Roof 4 100 30 5 15 4 6 NOTE Whe...

Страница 21: ...he 45 vent terminal and the exterior wall see Figure 7 must be at least 1 in 2 5 cm Use the proper cement and assembly procedures to secure the vent connector joints between the terminal and the blowe...

Страница 22: ...the necessary holes through the roof and ceiling and install the vent connector as shown in Figure 8 Make sure that the installation meets the local codes and or The National Fuel Gas Code ANSI Z223 1...

Страница 23: ...shown below see Figure 9 Refer to Table 7 for maximum venting lengths using 2 5 1 cm vent pipe or Table 8 for maximum lengths using 3 7 6 cm vent pipe 2 VENT INSTALLATION 3 VENT INSTALLATION Figure 9...

Страница 24: ...LLATIONS Terminating Reduce 3 to 2 Reduce 7 6 cm to 5 1 cm of Elbows Maximum Length ft m Minimum Length ft m 2 90 Elbows with Vent Terminal 1 100 30 5 10 3 1 2 90 Elbows with Vent Terminal 2 95 29 0 1...

Страница 25: ...applicator tools to ensure proper preparation and joining of pipe and fittings a Cutting Tools i A square cut must be achieved with a miter box saw or pipe cutter to ensure a proper mating with the f...

Страница 26: ...at around the end of the pipe 4 Joining a Joints should be made immediately after cement is applied b After fully inserting pipe into fitting socket hold joint together for about 15 to 20 seconds c Re...

Страница 27: ...le weather stripping heavily insulated caulked vapor barrier etc additional air may need to be provided using the methods described under CONFINED SPACES All Air From Outdoors or Specially Engineered...

Страница 28: ...ly or by ducts with the outdoors or spaces crawl or attic that freely communicate with the outdoors 1 When directly communicating with the outdoors each opening must have a minimum free area of 1 squa...

Страница 29: ...on DO NOT operate this water heater in a closed system without provisions for controlling thermal expansion Your water supplier or local plumbing inspector should be contacted on how to control this s...

Страница 30: ...relief valve into the opening provided and marked for this purpose on the water heater Note Some models may already be equipped or supplied with a combination temperature and pressure relief valve Ve...

Страница 31: ...scalds Water temperature over 125 F Feel water before bathing or before setting temperature are available showering Temperature limiting valves Review this instruction manual at water heater scalded A...

Страница 32: ...pply pipe dope to the gas valve inlet and make certain that no pipe dope has become lodged in the inlet screen of the gas valve Extreme care must be taken to ensure no pipe dope enters the gas valve A...

Страница 33: ...a switch that is used to turn on and off lights If wiring in conduit is required cut the flexible line cord flush with the bushing Remove the junction box cover and pull the pressure switch outside of...

Страница 34: ...34 Wiring Diagram Figure 10...

Страница 35: ...ter heater 3 Close the cold water supply shut off valve 4 Open the drain valve on the water heater by turning the stem counter clockwise The drain valve has threads on the end that will allow the conn...

Страница 36: ...36 Lighting and Shutdown instructions...

Страница 37: ...11 DANGER Hotter water increases the risk of scald injury Scalding may occur within five 5 seconds at a temperature setting of 140 F 60 C To protect against hot water injury install an ASSE approved m...

Страница 38: ...adjustable air shutter See Figure 12 At periodic intervals a visual check of the main burner and pilot flames should be made to determine if they are burning properly The main burner flame should lig...

Страница 39: ...ames to determine that they are burning properly See Burner Flame Check section on page 38 If sooting or other burner anomalies are evident shut down the water heater by turning off the gas per the in...

Страница 40: ...omponents which are not exact duplicates of Thoroughly inspect and replace as needed burner inner door gasket and or sight window gasket any time burner inner door is removed or disturbed Replace wate...

Страница 41: ...installed to extend tank life The anode rod should be inspected periodically every 2 years and replaced when necessary to prolong tank life Water conditions in your area will influence the time inter...

Страница 42: ...pplier Supplier Phone No CAUTION FOR YOUR SAFETY DO NOT ATTEMPT REPAIR OF COMBINATION GAS CONTROL BURNERS OR GAS PIPING REFER REPAIRS TO A QUALIFIED SERVICE TECHNICIAN Manufactured under one or more o...

Страница 43: ...use Pressure switch not working closed position 1 Pressure switch tubing kinked or blocked 2 Blocked pressure tap on switch 3 Faulty pressure switch Three flashes three second pause Pressure switch or...

Страница 44: ...ired false pilot flame sensed System auto resets Pilot valve stuck in open position Seven flashes three second pause Flammable vapor sensor fault detected see warning label 1 Flammable vapor present 2...

Страница 45: ...moving combustion air through the combustion system 5 The pressure switch closes 6 The control senses the closed pressure switch and starts the ignition process by providing a spark at the pilot elect...

Страница 46: ...tch 14 Pilot Assembly 4 Flue Baffle 15 Main Burner Orifice 5 Honeywell Gas Control Valve 16 Gas Feedline 6 Drain Valve 17 Flammable Vapors Sensor 7 Fiberglass Insulation not shown 18 Sensor Harness 8...

Страница 47: ...used for boiler treatment must not be introduced into potable water used for space heating 3 This water heater must not be connected to an existing heating system or component s previously used with...

Страница 48: ...48 NOTES...