![Bradford White 51000B Скачать руководство пользователя страница 10](http://html1.mh-extra.com/html/bradford-white/51000b/51000b_install-instructions-manual_2799594010.webp)
10
Venting continued-
Vent pipes serving power vented appliances are classified by building codes as
“vent connectors”. Required clearances from combustible materials must be
provided in accordance with information in this manual under LOCATION OF
WATER HEATER and CLEARANCES, and with National Fuel Gas Code and
local codes.
All vent pipes and terminals are to have a 1” minimum clearance to
combustibles. DO NOT use the placement of insulation or other materials in the
required clearance spaces surrounding the venting to combustible material
unless otherwise specified.
WARNING
Risk of carbon monoxide poisoning or fire due to joint separation
or pipe breakage.
This water heater must be properly vented and connected to an
approved vent system in good condition.
DO NOT
operate water heater
with the absence of an approved vent system. A clean and
unobstructed vent system is necessary to allow noxious fumes that
could cause injury or loss of life to vent safely and will contribute toward
maintaining the water heater’s efficiency. The acceptance of the
venting system is dependent upon full compliance with these installation
instructions.
Venting system
must not
pass through rated fire separations.
The venting system must be free to expand and contract. This venting
system
must be
supported in accordance with these instructions.
NOTICE
Single Wall Polypropylene venting systems that are listed on the
Bradford White website are approved for use in the water heaters
covered in this instruction manual. The venting system components are
ULC S636 approved and listed by a recognized agency and may be
installed in the U.S. and Canada. Complete instructions for the
approved venting systems can be found on the Bradford White website,
bradfordwhite.com or by calling the Technical Service Department
at:800-334-3393.
WARNING
The approved polypropylene venting system Instruction Supplement
listed on the Bradford White website for each manufacturer’s venting
system must be carefully read and followed by a qualified installer.
Failure to properly install the vent system may result in property
damage, personal injury, or death. The approved polypropylene venting
system Instruction Supplement listed on the Bradford White website for
each manufacturer’s venting system must be carefully read and
followed by a qualified installer. Failure to properly install the vent
system may result in property damage, personal injury, or death.