12
Most of these parameters can be adjusted with the
Multi Function Controller
and our
Remote Camera Panel
. Virtually any setting value can be requested from the unit.
In addition to the parameters above,
there are numerous ‘engineering’ commands. Setting
the PID values for Pan & Tilt, for example.
LCD Display
The LCD display on the side of the unit shows both operational and diagnostic information on
several pages. The pages are scrolled using the
Echo Head Display
function in the MFC
main menu.
For diagnostic purposes the cover over the display can be removed and there are
Page up
and
Page down
buttons on the PCB. The display also shows many of the internal registers
and settings. These values may assist in diagnosing any issues that may arise.
BR Remote
technicians will guide you through this process if needed.
A useful page is the Data Input page. This shows the data sent form the controller in Dstar
format.
Pre-Set Positions & Profile Moves
Up to 64 pre-set positions can be stored and recalled in the head. (dependent on controller)
Each position includes, Pan, Tilt, Zoom and Focus positions. Once stored, the positions are
saved during power loss. Simply drive the head to the required position and
Store
this
position as a Pre-Set.
A major feature of the
Proteân XMi
is that it always does a
Smooth
Profile Move
to
each
pre-set position. The profile of this move can be specified by the operator using the
Multi
Function Controller
. All axes, Pan, Tilt, Zoom & Focus, default to move in the same amount
of
time
to the pre-set position. The Zoom can be adjusted to start and stop before or after
the main pan/tilt move.
Default Total Time
= 4.5sec.
Default Ramp Up
= 1.5sec.
Default Ramp Down
= 1.5sec.
These settings are automatically stored but
can be adjusted at any time from the
Multi
Function Controller
Total Time, Ramp Up
time, and Ramp Down time, Zoom Start and
Zoom Stop can be adjusted by the operator
for each pre-set position independently.