background image

2

block-type installation, program all
entry panels first.
If there is an IPD/300LR porter
switchboard and IOD/303LR
accessories, they will be program-
med automatically on exiting pro-
gramming.

1 - PROGRAMMING 
RECEIVERS

1.1

- Enter 

receiver

programming

mode (yellow LED flashes).

1.2

- Lift the handset of the receiver to

be programmed.

1.3

- Press the two receiver buttons 

and 

at the same time for at least

1 s; 

the unit communicates with the system
300 entry panel or porter (default set-
ting entry panel n. 1).

1.4

- Make the relevant call from the

entry panel or IPD/300LR, if fitted;

the receiver sounds to confirm the pro-
gramming.

1.5

- Repeat the operations in points

1.2, 1.3 and 1.4 for all the receivers.

1.6

- Exit programming mode.

NOTA. You can change the default
entry panel used to program the
users by selecting any of the system
300 entry panels or the IPD/300LR
switchboard, if there is one (see
chapter 5-ALTERING DEFAULT
USER PROGRAMMING DEVICE).
If you decide to program receivers
from X2 blocks, follow the instruc-
tions provided with the X2 entry
panel.

2 - PROGRAMMING 
SYSTEM 300 ENTRY PANELS,
MASTER X2 
BLOCK ENTRY PANELS

Besides determining the entry panel
scanning order, programming lets you
set the type of system 300 entry panel
(with or without a surveillance camera),
duration of the solenoid door lock
command (the latter is only for system
300 pushbutton panels), and the num-
ber of X2 blocks in the system.

Proceed as follows:

2.1

- Enter 

entry panel programming

mode

(yellow LED on).

System 300 entry panels 
(ICP/LR or HAC/300LR)

(fig. 3)

The line engaged indicator light (if pre-
sent) lights up on pushbutton panels,
whilst the SETUP MODE message is
displayed on digital entry panels.

2.2

- Programming 

entry panel

and

door lock release time.

• Programming entry panel with sur-
veillance camera and door lock release
time 1 s.
- Press call button n.1.

Wait for audible confirmation: two
notes.

• Programming entry panel with no
surveillance camera and door lock
release time 1s.
- Press call button n.1.

Wait for audible confirmation: two
notes.

- Press call button n.1 again.

Wait for audible confirmation: one
note.

NOTE. If you wish to alter the door
lock release operating time from 1 s
to 4 s, 8 s or 16 s, carry out the above
operations in point 2.2 or 2.3 using
call buttons n. 2, 3 and 4 respectively.

2.3

- Repeat the procedure in 2.2 for

the remaining entry panels (in the order
in which the entry panels are to be
scanned).

Once the procedure is finished, the
engaged indicator light goes off or the
SETUP MODE message disappears to
indicate that programming is complete.

Master X2 block entry panels
(HEV/301, HEC/301, AZV/304, etc.)

(fig. 3)

WARNING. X2 block entry panels
can only be programmed with ver-
sion 3.0 units or later versions.

2.4 

- To set each Master X2 block

entry panel, two procedures are
necessary, given below.

A - Identification of block entry
panel.
B - Setting of number of user calls
in the block.

A - Identification 
of block entry panel

1 -

Remove and replace jumper

SW2 (receiver programming mode)
on the first 

Master entry panel

only (the one connected to the
XA/300LR power supplier, fig. 3)
belonging to the first X2 block and
await confirmation;

confirmed by double audible signal
and the solenoid door lock release
command being activated.

B - Definition of number 
of user calls in the block

This programming is performed,
again from the Master entry panel,
proceeding as follows:
1 -

Set number of buttons used on

audio/video panel (0, 1, 2, 3 or 4):
- press the last button used on the
audio/video panel (fig.4); if there isn’t
one, press the first button on the addi-
tional panel (fig.4).

2 -

Set total number of user calls in the

block:
- press the last call button used.

2.5

- Repeat the procedure in point

2.4 for the following first 

Master

entry panels

belonging to the other

blocks.
Programming of other 

Slave entry

panels

belonging to the same block

(fig. 3) must be performed afterwards
(see 

“Programming X2 Slave entry

panels”

section).

2.6

- Exit programming mode.

Sample settings of number 
of user calls

EXAMPLE 1 - X2 block featuring
Targha audio-only entry panel with 3
calls, with no additional pushbutton
panels (fig. 5).

3

1

2

3

4

5

6

9

8

7

0

C

T

S

P

HPV/1+
HAV/200+
HIA/300+
ICP/LR+
...HEP/306+
...HTS

HPV/1+
HAV/200+
HIA/300+
HAC/300LR+
2HTS

XA/300LR

Master

Slave

Slave

Slave

ICB/300

IPD/300LR

XAV/300

Master

Master and Slave entry panels:

HEV/301, HEC/301, HET/301, AZV/304, AZ/304. 

X2 Block  - 2

X2 Block X2 - 1

Porter
switchboard

300 entry panels

RESIDENTIAL INSTALLATION WITH X2 BLOCKS

X2 block
entry
panels

X2 block
entry
panels

Audio/video panel

(max 4 buttons)

HEV/301
HET/301

HEC/301

AZV/304

AZ/304

Additional
panel

HEP/306
HEP/312D
VZS/308C
or digital
HAC/300LR

4

Содержание XA/300LR

Страница 1: ...s per block personalizzazione tempo di attivazio ne impianto e durata chiamata programming all receivers using a programmer in this case you will need to collect the ID codes and enter them in the tab...

Страница 2: ...erations in point 2 2 or 2 3 using call buttons n 2 3 and 4 respectively 2 3 Repeat the procedure in 2 2 for the remaining entry panels in the order in which the entry panels are to be scanned Once th...

Страница 3: ...audio video panel Wait for audible confirmation 2 Then press call button n 10 posi tion 2E to set the total number of user calls used 10 Wait for audible confirmation WARNING If there is a porter swit...

Страница 4: ...a tecla de todas las placas exteriores 300 y X2 como llamada conserje CARACTER STICAS DE LAS INSTALACI N CON PROGRAMACI N EN MODO AMPLIADO En esta modalidad es posible ampliar las caracter sticas de l...

Страница 5: ...a programaci n Placas exteriores de bloque X2 HEV 301 HEC 301 AZV 304 etc fig 3 ATENCI N La programaci n de las placas exteriores de bloque X2 ser posible s lo con los aparatos versi n 3 0 o sucesivas...

Страница 6: ...ster la conectada con el unidad de control XA 300LR del blo que X2 4 3 Esperar la confirmaci n ac stica El n mero de notas ac sticas es igual que el n mero total de placas exterio res X2 conectadas co...

Страница 7: ...os conectables sobre la l nea X2 B 100 videointercomunicacions 200 telefonos Derivados internos activables con la misma llamada 3 8 con por lo menos 6 derivados con nota atenua da Temperatura de funci...

Страница 8: ...DIOINTERCOMUNICACION pag 11 15 VIDEOINTERCOMUNICACION pag 16 31 0 28 1 2 5 30 30 100 100 250 Cross section of the supply line wires Secci n de los conductores de la l nea de alimentaci n Distance Dist...

Страница 9: ...nductores correspondientes a los cableados CN2 CN3 para las conexiones de la interfaz HIA 300 a las unidades insta ladas en la placa exterior HPV 1 y HPC 1 ATENCI N El conductor de conexi n var a en f...

Страница 10: ...AE ICP LR MC 304 L CBO CBO MC 304 CBI CBO CBI 12 Fig 12 13 Connection diagram of auxiliary door lock release button AE Fig 12 13 Esquema de conexi n del pulsador auxiliar abrepuerta AE AE ICP LR L CBO...

Страница 11: ...5 21 8 11 12 14 1 CBI CN1 HEP 306 HEP 312D CN3 CN2 HIA 300 A V OUT V IN 3 4 CB CBO CBO 0 1 2 3 4 SW3 4 2 3 G V S B A N M R C G 5 21 SW1 NC 321 CP B M1 3 120 120 L N CP Personal door bell button Pulsad...

Страница 12: ...W1 B M1 SW1 YC 300 YC 300A YC 300 YC 300A SW1 NC 321 CP B M1 5 SE 300C02 2 UL MULTI FLAT AUDIO ENTRY INSTAL LATION WITH 2 ENTRANCES EQUIPO DE AUDIOINTERCOMUNI CACION MULTIFAMILIAR CON 2 ENTRADAS SE 30...

Страница 13: ...CBO CBO MC 304 CBI CBO ICP LR L 12V 2 1 C XA 300LR B A A L CNV B CNS HPC 1 HA 200 HIA 300 ICP LR KHPS KHPD HTS KHSO HEP 306 HEP 312D HA 200 5 21 8 11 12 14 1 CBI CN1 HEP 306 HEP 312D CN3 CN2 CBI CBO 2...

Страница 14: ...W1 B M1 SW1 YC 300 YC 300A YC 300 YC 300A SW1 NC 321 CP B M1 5 SE 300C03 2 UL MULTI FLAT AUDIO ENTRY INSTAL LATION WITH 3 ENTRANCES EQUIPO DE AUDIOINTERCOMUNI CACION MULTIFAMILIAR CON 3 ENTRADAS SE 30...

Страница 15: ...HEP 306 HEP 312D HA 200 5 21 8 11 12 14 1 CBI CN1 HEP 306 HEP 312D CN3 CN2 2 KHSO HIA 300 A V OUT V IN 3 4 CB CBO 0 1 2 3 4 SW3 ICP LR TMP TTS ICP LR MVA 300 MC 304 MVA 300 A MC 304 L CBI CBO CBI CBO...

Страница 16: ...3 SW1 B M1 SE 300V04 1 A UL SE 300V04 1 UL MULTI FLAT VIDEO ENTRY INSTAL LATION USING A CAMERA SEPARA TED FROM THE ENTRY PANEL CEN TRALIZED VIDEO HANDSETS POWER SUPPLY EQUIPO DE VIDEOINTERCOMUNI CACIO...

Страница 17: ...3 SW2 XC XT SW1 B M1 B B SE 300V04 1 A UL CP 1 2 OUT B M1 M2 SW0 SW2 SW4 SW3 1 SW1 XDV 304 YVM 300 SW3 SW1 B M1 SW3 SW1 B YKP 300 YV M1 CP CN1 CN1 M1 B M1 NVM 300 NC 321 3 4 IN SW1 SW1 SE 300V04 1 B U...

Страница 18: ...L 12V HPC 1 HA 200 HIA 300 ICP LR KHPS KHPD HTS HEP 306 HEP 312D HA 200 5 21 8 11 12 14 2 CBI CN1 HEP 306 HEP 312D CN3 CN2 HIA 300 A V OUT V IN 3 4 CB CBO CBO B VLS 101 B V V A 1 2 3 1 2 3 4 5 0 1 2 3...

Страница 19: ...M1 NVM 300 NC 321 SW1 SW1 YVM 300 SW3 SW1 B M1 SE 300V05 1 A UL SE 300V05 1 UL MULTI FLAT VIDEO ENTRY INSTAL LATION WITH 1 ENTRANCE CEN TRALIZED VIDEO HANDSETS POWER SUPPLY EQUIPO DE VIDEOINTERCOMUNI...

Страница 20: ...3 SW2 XC XT SW1 B M1 B B SE 300V05 1 A UL CP 1 2 OUT B M1 M2 SW0 SW2 SW4 SW3 1 SW1 XDV 304 YVM 300 SW3 SW1 B M1 SW3 SW1 B YKP 300 YV M1 CP CN1 CN1 M1 B M1 NVM 300 NC 321 3 4 IN SW1 SW1 SE 300V05 1 B U...

Отзывы: