OPERATING INSTRUCTIONS FOR 

SWIMMING POOL HEAT EXCHANGERS 

___________________________________________________________________ 

 

After the heat exchanger has been correctly installed, emphasis should be given to the general 
maintenance of all the pool equipment, the most important factor which will have a direct 
bearing on this will be the pool water condition. The proper purification of the pool water will 
allow for a healthier pool, the water will not cause discomfort to bathers, it will not cause a 
break-down of pool equipment and will not cause any unpleasant smells which are often 
experienced with wrong chlorine dosage. The ideal pool pH should be kept to within 7.4 to 
7.6. On no account should it fall below 7.2 or above 7.8. If this is not achieved 
corrosion/erosion of the pool equipment will occur. 

 

Listed below are some guides on operating conditions for the heat exchanger: 

 

a.  Always keep pH to within correct levels. Check on a day-to-day basis. Alter pool 

condition as necessary. 

 

b.  Ensure the free chlorine levels are within the range recommended by the chemical 

manufacturer and are in accordance with the type of pool, for example, private, 
hotel, school or municipal. 

 

c.  If a by-pass is fitted to the heat exchanger circuit, it is essential that any valves are 

correctly positioned and allow the recommended pool water flow to pass through 
the heat exchanger. Incorrect flows may cause corrosion/erosion. 

 

d.  The filter unit should be checked regularly. This is very important especially with 

sand filters. This sort, if working incorrectly, can allow sand to pass around the 
pool circuit causing erosion of pipe work, heat exchanger and pump unit. 

 

e.  Keep pool free from debris such as leaves, grass cuttings etc. This foreign matter 

can decay and increase pH: 

 

f. 

It is essential that the correct amount of chlorine dosage is added to the pool. To 
allow proper dispersion of the dose in the pool water; distribute the chemicals to 
various areas of the pool. Do not dose in one area only, as this will create high acidic 
areas which can cause corrosion/erosion of the pool equipment. 

 

Pool water which is in an unbalanced condition will prove costly for the owner with the 
replacement of pool components. It is essential that the manufacturers instructions are 
followed correctly as this will give safe bathing and prolong the life of all pool 
equipment. 

 

 

 

 

 
 
 
 
 

Содержание 4111-2

Страница 1: ......

Страница 2: ...débits plus importants sont possibles dans les limites imposées par les dimensions des orifices Dans le cas des applications où l eau de las piscine provient d un dispositif à énergie solaire nous pouvons fournir des échangeurs plus longs afin d utiliser au mieux l eau à température plus basse qui provient des panneaux solaries L eau de piscine tend à s acidifier lorsque l on a recours à la chloru...

Страница 3: ... 3706 2 9 358 202 190 G1 76 63 67 G2 M8 108 3707 2 16 472 294 190 G1 76 75 80 G2 M8 126 3708 2 26 502 272 108 G1 120 90 100 G3 M10 162 3709 3 44 674 370 236 G2 120 110 120 100mm M12 198 3711 3 65 704 340 236 80mm 150 130 140 125mm M16 232 3710 3 102 754 330 236 100mm 180 155 170 150mm M16 278 Flange to BS4504 table 6 Flansch gemäss DIN 2631 ...

Страница 4: ...AN12NT 3444 3TN1B EC12 783 3CI HS06x30 3706 2 FC033 1176CI OS46NT 3445 2TN1B FC10 1200 2CI HS08x35 3707 2 FG007 2802CI OS52NT 3446 2TN1B FG10 1650 2CI HS08x35 3708 2 GL037 3140CI OS56NT 3447 2TN1B GL15 3136 2CI HS10x40 3709 3 GK063 3255CI OC69NT 3448 3TN1B GK19 2865 3CI HS12x50 3711 3 JK004 3331CI OS74NT 3449 3TN1B JK19 3332 3CI HS16x70 3710 3 PK004 2926CI OS81NT 3450 3TN1B PK19 2919 3CI HS16x70 W...

Страница 5: ...mical manufacturer and are in accordance with the type of pool for example private hotel school or municipal c If a by pass is fitted to the heat exchanger circuit it is essential that any valves are correctly positioned and allow the recommended pool water flow to pass through the heat exchanger Incorrect flows may cause corrosion erosion d The filter unit should be checked regularly This is very...

Страница 6: ... 125 5 0 75 62 800 73 250 000 114 25 000 3706 2 4 20 938 3 0 45 17 00 3 750 7 1 04 75 700 88 300 000 137 30 000 3707 2 5 70 1 250 2 0 30 22 80 5 000 7 1 04 100 700 117 400 000 182 40 000 3707 2 7 20 1 562 4 0 60 28 44 6 250 11 1 65 125 600 146 500 000 228 50 000 3708 2 9 90 2 188 4 0 60 39 60 8 750 8 1 12 176 400 205 700 000 319 70 000 3709 3 12 60 2 812 5 0 75 51 00 11 250 7 1 04 226 300 263 900 ...

Отзывы: