Assembly / Owner’s Manual
51
Troubleshooting
Condition/Problem
Things to Check
Solution
No display/partial display/unit
will not turn on
Check electrical (wall) outlet
Make sure unit is plugged into a functioning wall outlet.
Check connection at front of unit
Connection should be secure and undamaged. Replace adapter or connec
-
tion at unit if either are damaged.
Check data cable integrity
All wires in cable should be intact. If any are visibly crimped or cut, replace
cable.
Check data cable
connections/orientation
Be sure cable is connected securely and oriented properly. Small latch on
connector should line up and snap into place.
Check console display for
damage
Check for visual sign that console display is cracked or otherwise damaged.
Replace Console if damaged.
Console Display
If Console only has partial display and all connections are fine, replace the
Console.
If the above steps do not resolve the problem, contact your local distributor
for further assistance.
Unit operates but Contact HR
not displayed
HR cable connection at Console Be sure cable is connected securely to Console.
HR cable box connection
Be sure cables from handlebars and cable to Console are secure and
undamaged.
Sensor grip
Be sure hands are centered on HR sensors. Hands must be kept still with
relatively equal pressure applied to each side.
Dry or calloused hands
Sensors may have difficulty with dried out or calloused hands. A conductive
electrode cream (heart rate cream) can help make better conduct. These are
available on the web or at medical or some larger fitness stores.
Static Handlebar
If tests reveal no other issues, Static Handlebar should be replaced.
Unit operates but Telemetric HR
not displayed
Chest Strap (optional)
Strap should be “POLAR
®
” compatible and uncoded. Make sure strap is
directly against skin and contact area is wet.
Check User Profile
Select the Edit User Profile option for the User Profile. Go to the WIRELESS
HR setting and make sure that the current value is set to ON.
Interference
Try moving unit away from sources of interference (TV, Microwave, etc).
Replace Chest Strap
If interference is eliminated and HR does not function, replace strap.
Replace Console
If HR still does not function, replace Console.
Unit operates but Telemetric HR
displayed incorrectly
Interference
Make sure that the HR receiver is not blocked by a personal electronic
device in the left side of the media tray.
No speed/RPM reading, Con
-
sole displays “Please Stride”
error code
Check data cable integrity
All wires in cable should be intact. If any are cut or crimped, replace cable.
Check data cable
connections/orientation
Be sure cable is connected securely and oriented properly. Small latch on
connector should line up and snap into place.
Check magnet position (requires
shroud removal)
Magnet should be in place on pulley.
Check Speed Sensor (requires
shroud removal)
Speed sensor should be aligned with magnet and connected to data cable.
Realign sensor if necessary. Replace if there is any damage to the sensor or
the connecting wire.
Содержание BXE226
Страница 1: ...ASSEMBLY OWNER S MANUAL BXE226 This product is compliant with the applicable CE requirements...
Страница 14: ...Assembly Owner s Manual 14 5 Attach Legs and then the Caps to Frame Assembly 7 10 A H B X2 6mm I X2 9 9...
Страница 18: ...Assembly Owner s Manual 18 9 Snap the Exterior Pivot Covers to Frame Assembly 3 19...
Страница 22: ...Assembly Owner s Manual 22 13 Set the Console Angle and Attach the Console Shroud to Frame Assembly 14...
Страница 62: ...Assembly Owner s Manual 62...
Страница 63: ...Assembly Owner s Manual 63...
Страница 64: ...8015020 041517 A EN...