9e947
c
11/24/17
6
ViewPoint Touch Screen Installation Instructions
An enclosure has been provided for the Ethernet
switch, and power supply. An Ethernet cable will be
run from the PC to the Ethernet switch. Also, an
Ethernet cable will run from the Smart Dairy
Controller to the switch. For each touch screen, an
Ethernet cable will also run to the switch.
The Ethernet switch has diagnostic lights
which indicate when the devices are
successfully connected and transmitting. The
connections can be hooked up after the
switch is wired for power and the power is
turned on.
-NOTICE-----------------------------
Maximum length for the power wires and Ethernet cable is 91m [300 ft].
Figure 3: Ethernet Switch detail
Figure 2: Power Supply wiring detail
24VDC 0VDC GND
VIEWPOINT
0VDC
VIEWPOINT
24VDC
+ - G