Page 4
40245-0-0219
INTRODUCTION
INSTRUCTIONS TO INSTALLER
1. Leave instruction manual with owner after installation.
2. Have owner register online or fill out and mail Product
Registration Card supplied with unvented fireplace.
3. This decorative front is for installation on an exterior wall only.
Consult the local Building Department regarding regulations,
codes or ordinances which apply to the installation of an
unvented fireplace with exterior decorative front.
The installation must conform with local codes or, in the absence
of local codes, with the National Fuel Gas Code, ANSI Z223.1.*/
NFPA 54.
*
Available from the American National Standards Institute, Inc.
1430 Broadway, New York, N.Y. 10018
.
BEFORE BEGINNING
This stainless steel exterior decorative front is designed to be
installed on an exterior wall of your residence. The fireplace
flame will be visible on a porch or area outside of the residence.
The other side will be inside the residence. Glass panels will
close off the exterior side of the fireplace and will act like an
exterior window. The heat from the fireplace will be projected
into the residence.
This kit includes an inner glass panel and frame that replaces
the screen frame assembly included with fireplace. It installs to
the fireplace first. The outer glass frame attaches to the fireplace
next, inside the exterior decorative front.
OPTIONAL ADDITION OF R-13 INSULATION
NOTICE:
Insulation is not required, but can help reduce your
heating and cooling bills.
•
Remove the decorative front from its packaging and place
exterior face down on scratch-free surface to protect the
stainless steel.
•
Remove black pan-head screws on outer glass-frame top
and sides.
•
Lift the metal filler and place to the side.
•
Cut strips of R-13 insulation to fit chambers inside t
he
decorative front. (See illustration). Remove the combustible
backing from the insulation and place insulation into channels.
•
Replace metal filler and attach with screws removed earlier.
4 5/8
”
22 3/8
”
64”
73 1/2
”
4 1/2
”
22 3/8
”
4 3/4
”
4 3/4
”
METAL FILLER
R13 INSULATION
(4) PIECES
OPTIONAL - ADDING R-13 INSULATION