background image

NOTICE!
Risk of fire
Do not block areas of ventilation. Do not install the device near any direct heat

source. Keep the device away from naked flames.

NOTICE!
Operating conditions
This device has been designed for indoor use only. To prevent damage, never

expose the device to any liquid or moisture. Avoid direct sunlight, heavy dirt, and

strong vibrations.

Safety instructions

 

DPX-620III 6-Ch.

13

dimmer pack

Содержание DPX-620III

Страница 1: ...DPX 620III 6 Ch dimmer pack User manual...

Страница 2: ...Musikhaus Thomann Thomann GmbH Hans Thomann Stra e 1 96138 Burgebrach Germany Telephone 49 0 9546 9223 0 E mail info thomann de Internet www thomann de 23 06 2020 ID 107858 V2...

Страница 3: ...1 3 Symbols and signal words 8 2 Safety instructions 10 3 Features 15 4 Installation and starting up 16 5 Connections and controls 19 6 Operating 23 7 Technical specifications 33 8 Plug and connectio...

Страница 4: ...4 DPX 620III 6 Ch dimmer pack...

Страница 5: ...vailable to all persons using this device If you sell the device to another user be sure that they also receive this manual Our products and user manuals are subject to a process of continuous develop...

Страница 6: ...Use the search function in the electronic version to find the topics of interest for you quickly Online guides Our online guides provide detailed information on technical basics and terms Personal co...

Страница 7: ...etterings for connectors and controls are marked by square brackets and italics Examples VOLUME control Mono button Texts and values displayed on the device are marked by quotation marks and italics E...

Страница 8: ...y an arrow Example 1 Switch on the device 2 Press Auto Automatic operation is started 3 Switch off the device 1 3 Symbols and signal words In this section you will find an overview of the meaning of s...

Страница 9: ...death or serious injury if it is not avoided NOTICE This combination of symbol and signal word indicates a pos sible dangerous situation that can result in material and environmental damage if it is...

Страница 10: ...be improper and may result in personal injury or property damage No liability will be assumed for damages resulting from improper use This device may be used only by persons with sufficient physical...

Страница 11: ...the unit They could swallow the pieces and choke Never let children unattended use electrical devices DANGER Electric shock caused by high voltages inside Within the device there are areas where high...

Страница 12: ...ble ends and screw terminals The connection of screw terminals as well as all maintenance and repair work on the electrical installation of the device must only be performed by qualified elec trical p...

Страница 13: ...t source Keep the device away from naked flames NOTICE Operating conditions This device has been designed for indoor use only To prevent damage never expose the device to any liquid or moisture Avoid...

Страница 14: ...the AC outlet is protected by a residual current circuit breaker Failure to do so could result in damage to the device and possibly injure the user Unplug the device before electrical storms occur and...

Страница 15: ...rial connector n Digital control system n Control via DMX 512 n Single channel fuse 6 A n Phase correction for linear dimming n Individually adjustable dimmer curve n Power supply via 5 pin mains conn...

Страница 16: ...dust and moisture during transportation or storage use the original packaging or your own packaging material suitable for transport or storage respectively Create all connections while the device is o...

Страница 17: ...in electric shock and risk of fire and loss of life By all means you have to observe all electrical safety instructions applicable at the place of operation The device is designed for mounting in 19 r...

Страница 18: ...Connect the output of the first DMX device to the input of the second one and so on to form a series connection Make sure that the output of the last DMX device in the chain is terminated by a resist...

Страница 19: ...5 Connections and controls Front panel Connections and controls DPX 620III 6 Ch 19 dimmer pack...

Страница 20: ...DMX signal is received 3 1 6 Voltage indicators of channels 1 6 The LEDs of active channels light solid green during operation 4 Display 5 CH 1 CH 6 Buttons for direct control of channels 1 6 6 Funct...

Страница 21: ...d for 5 pin CEE plug 40 A Phase 3 230 V 8 Dimmer outputs 16 pin multi pin industrial connector note the device label when connecting the cables Rear panel Connections and controls DPX 620III 6 Ch 21 d...

Страница 22: ...9 DMX IN DMX input 10 ANALOG Connections to control the device by a voltage in the range 0 V 10 V 11 DMX OUT DMX output Connections and controls 22 DPX 620III 6 Ch dimmer pack...

Страница 23: ...ANGER Hazardous voltage Hazardous voltage may be present at cable ends and screw terminals The connection of screw terminals as well as all maintenance and repair work on the electrical installation o...

Страница 24: ...C to reverse the direction of change Press one of the channel buttons UP or DOWN to increase or decrease the brightness of all channels together Pressing briefly results in changes with small incremen...

Страница 25: ...ndent DMX addresses are independent of each other Confirm with MENU 4 In Start mode Use UP or DOWN to select the DMX address of channel 1 in a rage 1 512 Confirm with MENU 5 In Independent mode Use UP...

Страница 26: ...channel whose DMX address is to be set Confirm with MENU Then select the DMX address for this channel from a range 1 512 Confirm with MENU and repeat the procedure for all channels 6 Press ESC to ret...

Страница 27: ...ween options n LastHold Last setting is retained n Analog The analogue control signal input ANALOG is analysed n Progr 01 12 The built in automatic programmes are executed Confirm with MENU 4 In Progr...

Страница 28: ...ividual maximum brightness Confirm with MENU 4 In All mode Use UP or DOWN to select the maximum brightness for all channels in a rage 70 100 Confirm with MENU In Independent Single mode Use UP or DOWN...

Страница 29: ...an individual minimum brightness Confirm with MENU 4 In All mode Use UP or DOWN to select the minimum brightness for all channels in a rage 0 30 Confirm with MENU In Single mode Use UP or DOWN to fir...

Страница 30: ...r curve and Single each channel can get an individual dimmer curve Confirm with MENU 4 In All mode Use UP or DOWN to select the dimmer curve from the options n Linear n S Curve n Non Dim n Square Conf...

Страница 31: ...n S Curve n Non Dim n Square Confirm with MENU and repeat the procedure for all channels 5 Press ESC to return to the main menu Operating DPX 620III 6 Ch 31 dimmer pack...

Страница 32: ...Menu overview Operating 32 DPX 620III 6 Ch dimmer pack...

Страница 33: ...connections Power supply 16 pin multi pin industrial connector Signal output DMX 512 via 3 pin XLR socket Channel fuse Circuit breaker MCB per channel Trigger characteristic C Rated current 16 A Numb...

Страница 34: ...llation 19 2 RU Dimensions W H D 482 mm 325 mm 88 mm Weight 13 5 kg Ambient conditions Temperature range 0 C 40 C Relative humidity 50 non condensing Technical specifications 34 DPX 620III 6 Ch dimmer...

Страница 35: ...ket the result of an incorrect connection may be a destroyed DMX controller a short circuit or just a not working light show The unit offers a 3 pin XLR socket for DMX output and a 3 pin XLR plug for...

Страница 36: ...and markings on the packaging This product is subject to the European Waste Electrical and Electronic Equipment Directive WEEE in its currently valid version Do not dispose with your normal household...

Страница 37: ...Notes DPX 620III 6 Ch 37 dimmer pack...

Страница 38: ...Notes 38 DPX 620III 6 Ch dimmer pack...

Страница 39: ......

Страница 40: ...Musikhaus Thomann Hans Thomann Stra e 1 96138 Burgebrach Germany www thomann de...

Отзывы: