Страница 2: ...nt operation 3 2 Overview 5 2 1 Front view 5 2 2 Rear view 6 2 3 Termination 6 3 Operating guide 7 3 1 Display and standby mode 7 3 2 Menu 7 3 2 1 DMX Fail 7 3 2 2 Patching 8 3 2 3 Minimum Level 10 3...

Страница 3: ...F 0 C or exceeding 104 F 40 C To avoid placing on un stable location Select a level and stable location to avoid vibration Do not use chemicals or volatile liquids for cleaning Use a clean dry cloth...

Страница 4: ...et by the manufacturer Important Damages caused by the disregard of this user manual are not subject to warranty The dealer will not accept liability for any resulting defects or problems Make sure th...

Страница 5: ...UP DOWN With this button you can increase decrease a value Pressing and holding the button will increase decrease the value quickly 5 ESC With this button you can exit the menu 6 Channel dimmer modul...

Страница 6: ...6 16 2 2 Rear view 1 Analogue input DC 0 10 V 2 DMX IN 3pol XLR input male 3 DMX OUT 3pol XLR output female 2 3 Termination...

Страница 7: ...10 11 and 12 3 2 Menu In standby mode tap MENU to enter the menu There are 6 menus DMX Fail Patching Minimum Level Maximum Level Preset and Curve all other menu settings will be stored into a memory T...

Страница 8: ...g 1 Press UP DOWN to get to the Patching menu 2 Tap MENU to enter sub menu You can use UP DOWN to choose between Start and Independent Start address Complete dimmer 12 channels has only one start addr...

Страница 9: ...P DOWN to select the DMX address from 001 512 In All mode complete dimmer 12 channels has only one start address 7 In Single mode tap MENU to select between channel and address In Single mode the DMX...

Страница 10: ...t into the menu 4 In All mode tap UP DOWN to select Minimum Level value of all channels between 00 30 5 In Single mode tap MENU to select between channel and Minimum Level value 6 When Chan is activat...

Страница 11: ...into the menu 4 In All mode tap UP DOWN to select Maximum Level value of all channels between 070 100 5 In Single mode tap MENU to select between channel and Minimum Level value 6 When Chan is activat...

Страница 12: ...3 Tap UP DOWN to select between All and Single Tap MENU to get into the menu 4 In All mode tap UP DOWN to select the dimming level value of all channels between 000 100 5 In Single mode tap MENU to se...

Страница 13: ...o select between Linear S Curve Non Dim and Square 5 In Single mode tap MENU to select between Linear S Curve Non Dim and Square 6 When Chan is activated tap UP DOWN to select from 01 12 when the dimm...

Страница 14: ...ut 10 A CH Total 120 A Voltage 32 A 400 V AC Connections Current in Terminal block Current out Terminal block XLR in out 3pol XLR Controlling Dimming curve Linear S Curve Switch Switch Square Automati...