3-15
Chapter 3 • Systems Overview and Operation
R
325 Conquest
Head System
Environmental Considerations
The Environmental Protection Agency (EPA)
standards state that in freshwater lakes, reservoirs,
impoundments whose inlets or outlets are such as
to prevent the ingress or egress by vessel traffic
subject to this regulation, or in rivers not capable
of navigation by interstate traffic subject to this
regulation, marine sanitation certified by the United
States Coast Guard (U.S.C.G.) installed on vessels
shall be designed and operated to prevent the
overboard discharge of sewage, treated or untreated
or any other waste derived from sewage.
The EPA standards further state that this shall
not be construed to prohibit the carriage of Coast
Guard certified flow through treatment devices
which have been secured so as to prevent such
discharges. They also state that the waters where
a Coast Guard certified marine sanitation device
permitting discharge is allowed include: Coastal
waters, Estuaries, The Great Lakes and Intercoastal
waterways, Freshwater lakes and Impoundments
accessible through locks and other flowing waters
that are navigable interstate by vessels subject to
this regulation. (40 CFR, 140.3)
This vessel is equipped with a waste containment/
disposal system. The system includes a VacuFlush
®
toilet, a 12 gal. (45L) holding tank with vacuum
pump, macerator, lockable discharge seacock,
dockside pump-out connection, and a thru-hull vent.
This boat is equipped with an overboard
discharge seacock. Severe state and federal
penalties are levied for discharging raw sewage
and solid waste in waters where it is not
permitted.
The macerator can be disabled by attaching a
wire tie or padlock to the seacock or removing
the seacock handle while in a closed position,
which would avoid potential fines.
It is illegal for any vessel to dump plastic trash
anywhere in the ocean or navigable waters of
the United States.
NOTICE
Macerator/Discharge Pump
The macerator/discharge pump (see Figure 3.15.1)
draws solid and liquid waste from the holding tank
and processes it prior to discharging it overboard
through the macerator seacock located in the aft bilge.
The macerator is designed to handle waste, toilet/
facial tissue and does not pump solid waste. The key
used to actuate the overboard discharge unit can be
found in the owner’s packet.
NOTICE
The low-water consumption waste system
requires the use of special paper to prevent
clogs. The manufacturer has provided
information regarding the type of paper that
must be used. Never use residential tissue
paper in your marine waste system.
Waste System
Figure 3.15.1
HOLDING TANK
DOCKSIDE PUMPOUT
LOCKABLE DISCHARGE SEACOCK
MACERATOR
1
1
2
2
3
4
4
3
FWD
!
CAUTION
The discharge seacock should always be in
the closed position when the toilet is not in
use. Failure to do so could result in flooding or
property damage.
Содержание 325 Conquest
Страница 1: ......
Страница 21: ...285 Conquest 325 Conquest R Introduction THIS PAGE INTENTIONALLY LEFT BLANK Intro 18...
Страница 46: ...1 25 Chapter 1 Safety 325 Conquest R THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 78: ...2 32 Chapter 2 General Information R 325 Conquest THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 113: ...3 35 Chapter 3 Systems Overview and Operation R 325 Conquest THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 131: ...4 18 Chapter 4 Electrical R 325 Conquest...
Страница 153: ...4 40 Chapter 4 Electrical R 325 Conquest Main DC Battery RBS DC joystick Figure 4 40 1...
Страница 154: ...4 41 Chapter 4 Electrical R 325 Conquest Main DC Battery RBS DC standard Figure 4 41 1...
Страница 155: ...4 42 Chapter 4 Electrical R 325 Conquest 30A Receptacle and Spotlight Power Jumper Figure 4 42 1...
Страница 156: ...4 43 Chapter 4 Electrical R 325 Conquest Bow Thruster DC Figure 4 43 1...
Страница 157: ...4 44 Chapter 4 Electrical R 325 Conquest Main DC Figure 4 44 1...
Страница 158: ...4 45 Chapter 4 Electrical R 325 Conquest DC Battery Layout Figure 4 45 1...
Страница 159: ...4 46 Chapter 4 Electrical R 325 Conquest Headliner DC Figure 4 46 1...
Страница 160: ...4 47 Chapter 4 Electrical R 325 Conquest Hardtop DC Figure 4 47 1...
Страница 161: ...4 48 Chapter 4 Electrical R 325 Conquest Cabin DC Figure 4 48 1...
Страница 162: ...4 49 Chapter 4 Electrical R 325 Conquest Stereo Amplifier DC Figure 4 49 1 Windlass DC Figure 4 49 2...
Страница 163: ...4 50 Chapter 4 Electrical R 325 Conquest Windshield Washer Wiper DC Figure 4 50 1...
Страница 166: ...4 53 Chapter 4 Electrical R 325 Conquest NAUTIC ON Bilge Pump Two Position Adaptor DC Figure 4 53 1...
Страница 167: ...4 54 Chapter 4 Electrical R 325 Conquest NAUTIC ON Bilge Pump Three Position Adaptor DC Figure 4 54 1...
Страница 168: ...4 55 Chapter 4 Electrical R 325 Conquest Battery Switch Panel with Gyroscopic Stabilizer DC Figure 4 55 1...
Страница 169: ...4 56 Chapter 4 Electrical R 325 Conquest Battery Switch Panel no gyroscopic stabilizer DC Figure 4 56 1...
Страница 170: ...4 57 Chapter 4 Electrical R 325 Conquest Head Switch Panel DC Figure 4 57 1...
Страница 171: ...4 58 Chapter 4 Electrical R 325 Conquest Cabin Breaker Panel DC Figure 4 58 1...
Страница 172: ...4 59 Chapter 4 Electrical R 325 Conquest Pilothouse CO Monitor DC Figure 4 59 1 Generator Switch Panel DC Figure 4 59 2...
Страница 173: ...4 60 Chapter 4 Electrical R 325 Conquest Helm Switch Panel DC Figure 4 60 1...
Страница 174: ...4 61 Chapter 4 Electrical R 325 Conquest Shore Power 1 and 2 with Generator 120V 60Hz AC Figure 4 61 1...
Страница 175: ...4 62 Chapter 4 Electrical R 325 Conquest Shore Power 1 and 2 no Generator 120V 60Hz AC Figure 4 62 1...
Страница 176: ...4 63 Chapter 4 Electrical R 325 Conquest Shore Power with Generator 120V 60Hz AC Figure 4 63 1...
Страница 177: ...4 64 Chapter 4 Electrical R 325 Conquest Shore Power no Generator 120V 60Hz AC Figure 4 64 1...
Страница 178: ...4 65 Chapter 4 Electrical R 325 Conquest Shore Power 1 Breaker Panel 120V 60Hz AC Figure 4 65 1...
Страница 179: ...4 66 Chapter 4 Electrical R 325 Conquest Shore Power 2 Breaker Panel 120V 60Hz AC Figure 4 66 1...
Страница 180: ...4 67 Chapter 4 Electrical R 325 Conquest Shore Power 1 AC System 120V 60Hz Figure 4 67 1...
Страница 181: ...4 68 Chapter 4 Electrical R 325 Conquest Shore Power 2 AC System 120V 60Hz Figure 4 68 1...
Страница 182: ...4 69 Chapter 4 Electrical R 325 Conquest Grill 120VAC and Fridge 12VDC Figure 4 69 1...
Страница 183: ...4 70 Chapter 4 Electrical R 325 Conquest Shore Power 1 and 2 with Generator 230V 50Hz AC Figure 4 70 1...
Страница 184: ...4 71 Chapter 4 Electrical R 325 Conquest Shore Power 1 and 2 no Generator 230V 50Hz AC Figure 4 71 1...
Страница 185: ...4 72 Chapter 4 Electrical R 325 Conquest Shore Power with Generator 230V 50Hz AC Figure 4 72 1...
Страница 186: ...4 73 Chapter 4 Electrical R 325 Conquest Shore Power no Generator 230V 50Hz AC Figure 4 73 1...
Страница 187: ...4 74 Chapter 4 Electrical R 325 Conquest Shore Power 1 Breaker Panel 230V 50Hz AC Figure 4 74 1...
Страница 188: ...4 75 Chapter 4 Electrical R 325 Conquest Shore Power 2 Breaker Panel 230V 50Hz AC Figure 4 75 1...
Страница 189: ...4 76 Chapter 4 Electrical R 325 Conquest Shore Power 1 AC System 230V 50Hz Figure 4 76 1...
Страница 190: ...4 77 Chapter 4 Electrical R 325 Conquest Shore Power 2 AC System 230V 50Hz Figure 4 77 1...
Страница 191: ...4 78 Chapter 4 Electrical R 325 Conquest Grill 230VAC and Fridge 12VDC Figure 4 78 1...
Страница 192: ...4 79 Chapter 4 Electrical R 325 Conquest Generator 120V 60Hz AC Figure 4 79 1...
Страница 193: ...4 80 Chapter 4 Electrical R 325 Conquest Generator 230V 50Hz AC Figure 4 80 1...
Страница 194: ...4 81 Chapter 4 Electrical R 325 Conquest Gyroscopic Stabilizer 120V 60Hz AC Figure 4 81 1...
Страница 195: ...4 82 Chapter 4 Electrical R 325 Conquest Gyroscopic Stabilizer 230V 50Hz AC Figure 4 82 1...
Страница 207: ...5 12 Chapter 5 Care and Maintenance R 325 Conquest Reinforcement Locations Figure 5 12 1 NOTE P S port and starboard...