Water Dispenses but not correct Temperature
Problem/
Report
Possible Cause
Suggested Action
Water Dispenses But Not Correct Temperature
Ambient Water
too warm
Low usage and / or fed
from water supply pipe in
warm ducting.
Advise user replacing external causes and
solutions.
Cold water not
Cold
Cooling and or Sparkling
System switched off.
Check switch positions on the back of the machine as
necessary.
Compressor runs and
switching off (cool/warm to
touch) - Thermostat set too
high.
Decrease Cold Thermostat set point.
Faulty Thermostat.
Replace Thermostat
Compressor runs but not
Switching off (Hot to touch).
Contact Aftersales Support.
Refrigeration problem.
Contact Aftersales Support.
Compressor not running at
all.
Check voltage path through the machine.
No electricity power supply.
Check power cord connected and live, and
machine is switched on.
Compressor only hums
slightly/ briefly.
Check and replace relays.
Relays loose.
Check and refit relays.
Compressor Faulty.
Contact Aftersales Support.
DC Tank Empty
Check water level and replace level control module in
fill valve as needed.