Introduction 

 

Please Note: This Product Manual is intended for use by qualified Service Technicians only. 
Use of the advice and material enclosed by the end-user could invalidate product warranty, 
occupational insurances and present health and safety risks. 
 
We strongly recommend that this Product Manual is not left with the dispenser or end-user but that 
instead training is given regarding the simple function operations.  
 

 

The Boste BK Series (UDC102 Model) is a range of undercounter water dispensers that are connected to the mains water 
supply and dispense water through a proprietary swan-neck faucet that is mounted on a worksurface.  
 
There are two models in the range: 
 
BK5 – Cold & Ambient  
 
BK9 – Cold, Sparkling & Ambient 
 
Both models models have robust steel framed cabinets and  attractively injection moulded plastic  front,  side  and  top 
panels.   
 
An IEC Power  Lead  is supplied for connection to the  IEC socket found  on the  rear of all models (An additional Schuko 
type is supplied for the  European market). 
 
Both are Direct  Chill cold water  dispenser where  water  is used  as  the  cooling  medium in the  Direct  Chill tank. 
This is automatically filled and  controlled by the  level control  system upon  installation.  This tank  is then  chilled  via 
the outer  evaporation coil of the  capillary  controlled refrigeration compression system. We recommend fitting a 
Pressure Reducing  Valve is fitted  to all supplies to regulate the  pressure to  3.5 bar/355  kPa.   
 
On the carbonated water model, water  is chilled  as  it passes through the  coil immediately before  dispense or 
being  pumped under  pressure into the carbonator which it fitted inside  the  same coil. The carbonator is also 
level controlled and  allows  the  sparkling effect to occur  through saturation with CO2. 
 
Dispense is at inlet  pressure and controlled via the  solenoid  valves. 
 
The Cold Temperature is thermostatically controlled via the  adjustment screw  on the  back  of the  machine.  This 
setting is factory  set  and  is not necessary to adjust  in most  cases  

 
The Cold Tank can  be drained via the  two Drain Port on the  rear of the  machine. 
 
The level control  system also  incorporates a leak  detection device within the  cabinet which switches the 
machine off in the  event  of detecting water. 

 
 

Содержание UDC102

Страница 1: ...1 PRODUCT MANUAL Boste BK Series UDC102 Undersink Dispenser Model ...

Страница 2: ...02 Models Contents 1 Introduction Page 3 2 Specifications Page 4 3 Main Components Page 5 4 Installation Guide Page 7 5 Operation Guide Page 8 6 Maintenance Guide Page 9 7 Fault Diagnosis Guide Page 10 8 Diagrams Parts Guide Page 16 ...

Страница 3: ...Direct Chill cold water dispenser where water is used as the cooling medium in the Direct Chill tank This is automatically filled and controlled by the level control system upon installation This tank is then chilled via the outer evaporation coil of the capillary controlled refrigeration compression system We recommend fitting a Pressure Reducing Valve is fitted to all supplies to regulate the pr...

Страница 4: ...m pump feeding carbonator on sparkling water machine option COLD TEMPERATURE 2 C to 11 C THROUGHPUT PER HOUR 18 litres cold 12 C 16 litres sparkling 12 C DISPENSE Swan Neck Faucet with ergonomically designed and situated light touch sensitive controls MAXIMUM RUNNING POWER CONSUMPTION 85 100 watt Cooling Additional intermittent carbonation usage POWER REQUIREMENTS 230 volt 50Hz 16A supply required...

Страница 5: ...m Insulated Water Pipe Also included Also included 2 0m x 1 4 Faucet Connection Pipe 3 0m x 1 4 Faucet Connection Pipe 1 0m Faucet Connection Pipe Insulation 2 0m Faucet Connection Pipe Insulation 2no 1 4 Stem Elbow 5no 1 4 Stem Elbow 1no 1 4 Y Fitting 1no 1 4 Cross Fitting 1no 1 4 Male Threaded Adaptor 1no 1 4 Male Threaded Adaptor 1no 6mm Female Threaded Adaptor 1no 6mm Female Threaded Adaptor M...

Страница 6: ...ecommend fitting a check valve a pressure reducing valve and a Waterbock device These are available as part of our optional Installation Kit When fitting a Waterblock device we recommend a minimum setting of 2 be used Pre flush and fit the filter in an accessible position and always allow adequate connecting pipe length to enable the unit to be sufficiently moved for any future disconnection Do no...

Страница 7: ...B Any immediate whining noise from the DC pump should soon stop as the water level in the system rises 16 Upon the filling cycle completing proceed to flush the cold and the ambient water channels using these buttons on the faucet control panel We recommend that a minimum of 10lts is flushed through the unit Cold approx 8 lts and Ambient approx 2 lts Switch on the Cooling Mode and allow up to 1 hr...

Страница 8: ...Mode on Bottom Cooling cycle on Cooling cycle on To dispense water simply press and hold the appropriate button for the duration of the required dispense Cold Ambient Model Cold Sparkling Ambient Model Top Ambient Ambient Middle N A Sparkling Bottom Cold Cold No other user operation function or adjustment is required Please Note The integrated leak prevention control will prevent any continuous di...

Страница 9: ...t 1 litre of water for the machine to ingest the solution Leave solution for 10 minutes inside machine for sanitisation to take effect During this time thoroughly clean the machine externally For this we recommend the use of proprietary disposable sanitisation wipes Pay particular attention to the dispense faucet and the push button controls Remember to include the drip tray If a Waste Overflow Sy...

Страница 10: ... Check if hole in centre of washer is clear Check valve action Carefully dismantle valve and clean out part replace complete replace as needed Valve not clicking Check voltage output when operated If no output replace PCB If there is output replace solenoid coil whole valve coil whole valve assembly complete Leak detector has disabled dispense operation Check for internal leakage ensure probes are...

Страница 11: ...as for Ambient Dispense Low or no CO2 pressure Check and replace cylinder as necessary Pump not operating Check carbonator level Control System Check probes connected leads attached Check power supply to pump Carbonator Tank over pressurised with CO2 Switch Sparkling System off shut off CO2 supply and release CO2 from carbonator Switch Sparkling system on then check pump operation If normal open C...

Страница 12: ...hing off cool warm to touch Thermostat set too high Decrease Cold Thermostat set point Faulty Thermostat Replace Thermostat Compressor runs but not Switching off Hot to touch Contact Aftersales Support Refrigeration problem Contact Aftersales Support Compressor not running at all Check voltage path through the machine No electricity power supply Check power cord connected and live and machine is s...

Страница 13: ...drain pipe is not blocked Water lying in bottom of machine Faulty Water System Level Sensor Check operation and replace batteries if needed Leak in supply inlet pipe work and or filter Locate and repair accordingly Leak from machine water pipe work fittings Locate and repair accordingly Check pressure and fit pressure reducing valve if needed DC tank over overfilling Check level control module and...

Страница 14: ... Check Fuse in IEC Socket Replace if necessary Faulty Control PCB Machine working normally otherwise Replace Control PCB Machine shakes on Start Up Compressor Starting Level Surface No action needed This is quite normal Uneven Surface Level up machine using adjustable feet Missing Fixings Replace missing fixings Tripping out Electricity supply Machine in high humidity environment Discuss possible ...

Страница 15: ...d button on to purge air out This could take several minutes where pressure is low Use filter function if available Button Not being pressed enough Press button firmly N B This could be caused by a surrounding cold environment making the action stiffer Faulty Control PCB Replace Control PCB From Ambient or Cold Water Valve and hammering noise Fluctuating mains water pressure situation Contact Azur...

Страница 16: ...Boste BK Series 16 Diagrams Parts Lists ...

Страница 17: ...17 ...

Страница 18: ......

Страница 19: ......

Страница 20: ......

Страница 21: ......

Страница 22: ...Boste BK UDC102 ...

Страница 23: ......

Страница 24: ......

Страница 25: ......

Страница 26: ......

Страница 27: ......

Страница 28: ...ELS Technical Support Available 0700 1700 Monday to Friday Telephone 0044 01362 695 006 Fax 0044 01362 656 920 Email aftersales azureuk co uk Synergy House Fakenham Road Morton On The Hill Norfolk NR9 5SP sales azureuk co uk www azureuk co uk ...

Отзывы: