12
GB
Plumbing equipment
Water line:
arrange your shower box with the water supply line and coupling for the showerhead. The
coupling must be above the ceiling. (Fig. 1).
The showerhead, which is installed parallel to the fl oor, supplies a “free falling” stream of water like
soft rain. We recommend that the faucet supplies at least 25 litres of water per minute. Naturally, the
higher the fl ow rate of the faucet, the better the showerhead will work. Also make sure that the hot
water heater supplies enough hot water for proper functioning.
Product
Flow Rates
Product Weight
Kg
Product Weight
with Water Kg
Dream Rect. 500x400 mm
min 16 L/min
7,70
9,20
Dream Oval 500x350 mm
min 16 L/min
5,50
6,90
Dream Cube 400x400 mm
min 16 L/min
6,40
7,60
Dream OKI Ø 400 mm
min 16 L/min
5,00
5,90
Dream Rect.-
Flat
570x470 mm
min 16 L/min
9,75
11,25
Dream Oval -
Flat
570x420 mm
min 16 L/min
6,40
7,80
Dream Cube-
Flat
470x470 mm
min 16 L/min
7,35
8,55
Dream OKI-
Flat
Ø 470 mm
min 16 L/min
5,75
6,65
Dream Rect. 400x300 mm
min 16 L/min
5,20
6,00
Dream Oval 400x250 mm
min 16 L/min
3,70
4,50
Dream Cube 300x300 mm
min 16 L/min
4,10
4,70
Dream OKI Ø 300 mm
min 16 L/min
3,40
3,90
Dream Rect. -
Flat
470x370 mm
min 16 L/min
6,00
6,85
Dream Oval -
Flat
470x320 mm
min 16 L/min
4,30
5,10
Dream Cube -
Flat
370x370 mm
min 16 L/min
4,85
5,45
Dream OKI -
Flat
Ø 370 mm
min 16 L/min
4,00
4,50
False ceiling
•Once the hydraulic systems are hooked up, realise the false ceiling with suitable reinforcement, as when
mounting a chandelier, and make sure it is perfectly level.
•Keep a distance of at least 12 cm between the ceiling and the false ceiling (Fig.1).
•Position the template, mark with a pencil the 6 attachment holes and the central beak-through that will
house the hydraulic parts of the showerhead (Fig.2).
•Make the 6 attachment holes having a 10 mm diameter (Fig. 3)
• Make the beak-through (Fig.3)
•Insert the 6 expansion screws and make sure that they are placed accurately (Fig.4).
Showerhead installation
•Insert the quick disconnect coupling (3), to the showerhead connection (2), and block the Allen screws
using their wrench (8). (Fig.A)
•Connect one end of the hose (4) to the showerhead connection (2) and the other end to the water supply
line on the wall. If there is a ½”F wall connection, use the adaptor (10) ½”M × ½”M that is included. (Fig.B)
•Lay the showerhead in correspondence of the 6 expansion screws that were previously inserted in the
false ceiling (dis 5), and tighten the 6 screws included until the showerhead is properly fi tted to the false
ceiling (dis .7). Make sure that the screws are fully tightened, about 16 full turns every screw (dis6).
INSTALLATION AND CARE INSTRUCTIONS