Boss Ecomaxx Скачать руководство пользователя страница 6

Page 

6

 of 

28

 

 

EM-NRV NORTH AMERICAN SUPPLEMENTAL MANUAL - V2016NRV-ELE

 

ECOMAXX EM-NRV  

NO RETURN VALVE SPECIFICATIONS 

 

STANDARD FEATURES (ALL SIZES) 

 

Heavy Duty Welded Steel Construction * Epoxy Powder Coated Safety Red Finish  

Flanged Inlet and Outlet with Co-Flanges * Grounding Lugs * Locking Mechanism(s) 

ATEX Certification 

 

 

Sizes 7” Thru 28” 

o

  Certified ATEX EN16447 & EN15089

 

  Certified: CE0477 

 II D

 

  Certified N. EUT 14 ATEX 1954

 

o

  Application Class: ST3 (Kst max 400 bar m/s)

 

o

  P

red

 Max: 0.5 Bar

 

o

  Maximum Velocity: 5905 FPM

 

o

  Maximum Pressure: 200.93” H

2

O / 14.76” Hg

 

o

  Process Temperature Range:  -4° F to 140° F (- 20° C to +60° C)

 

o

  Pressure Drop @ 5905 FPM (Sizes 7” - 18”): 0.25” H

2

 

o

  Pressure Drop @ 5905 FPM (Sizes 20” - 28”): 0.40” H

2

O

 

o

  Minimum Distance (Sizes 7”- 16”) From Collector: 2 meters / 6.56 feet

 

o

  Maximum Distance (Sizes 7”-16”) From Collector: 4 meters / 13.12 feet

 

o

  Minimum Distance (Sizes 18”- 28”) From Collector: 3 meters / 9.84 feet

 

o

  Maximum Distance (Sizes 18”-28”) From Collector: 6 meters / 19.69 feet

 

o

  Horizontal Installation Only

 

 

 

Sizes 32” Thru 40” 

o

  Certified ATEX EN15089

 

  Certified: CE2049 

 II D

 

  Certified N. EUM1 12 ATEX 0714

 

o

  Application Class: ST2 (Kst max 299 bar m/s)

 

o

  P

red

 Max: 0.25 Bar

 

o

  Maximum Velocity: 5905 FPM

 

o

  Maximum Pressure: 100.47” H

2

O / 7.38” Hg

 

o

  Process Temperature Range:  -4° F to 140° F (- 20° C to +60° C)

 

o

  Pressure Drop @ 5905 FPM: 0.63” H

2

 

o

  Minimum Distance From Collector: 3 meters / 9.84 feet

 

o

  Maximum Distance From Collector: 6 meters / 19.69 feet

 

o

  Horizontal Installation Only

 

 
 

Содержание Ecomaxx

Страница 1: ...ES 12 THRU 13 PAGES 14 THRU 17 PAGES 18 THRU 20 ASSEMBLY INSTRUCTIONS SIZES 12 THRU 28 ASSEMBLY INSTRUCTIONS SIZES 32 THRU 40 INSTALLING THE MICROSWITCH O EM NRV MS PAGES 21 THRU 22 INSTALLING THE DUS...

Страница 2: ...a period of 12 months from the shipping date so long as Buyer can demonstrate i that such material was installed in accordance with the National Electrical Code NFPA guidelines and local codes and or...

Страница 3: ...MANUAL IS A SUPPLEMENT TO THE AIRCOM INSTALLATION USE AND MAINTENANCE MANUAL FOR NO RETURN VALVES IT HAS BEEN COMPILED BY BOSS PRODUCTS LLC FOR THE NORTH AMERICAN MARKET THE INSTALLER AND END USER MU...

Страница 4: ...PRIATE PPE REQUIRED FOLLOW ALL REQUIREMENTS IN NFPA 70E ALWAYS MAINTAIN PROPPER CONVEYING VELOCITIES AS REQUIRED BY NFPA 652 654 FOR COMBUSTIBLE DUSTS WARNING DO NOT SUBSTITUTE COMPONENTS READ ALL DIS...

Страница 5: ...s and conveying ductwork per 12 2 3 4 6 KEY POINTS 12 2 3 4 2 Requires a locking mechanism which is provided standard 12 2 3 4 3 Requires an Inspection door which is provided standard 12 2 3 4 4 Requi...

Страница 6: ...05 FPM Sizes 7 18 0 25 H2O o Pressure Drop 5905 FPM Sizes 20 28 0 40 H2O o Minimum Distance Sizes 7 16 From Collector 2 meters 6 56 feet o Maximum Distance Sizes 7 16 From Collector 4 meters 13 12 fee...

Страница 7: ...11 8 7 6 6 45 EM NRV10 9 84 250mm 16 1 15 3 23 6 15 3 12 7 8 7 6 56 EM NRV12 11 81 300mm 18 1 17 3 26 3 23 6 13 7 9 8 6 4 5 84 EM NRV14 13 78 350mm 20 19 2 28 3 25 5 14 7 10 9 6 4 5 100 EM NRV16 15 75...

Страница 8: ...provided with EM NRV Model I D 1 I D 2 B C O D Holes Thickness EB FL07 7 20 7 125 8 38 9 56 5 0 4 0 15 EB FL08 7 99 8 125 9 17 10 35 6 0 4 0 15 EB FL10 9 96 10 125 11 14 12 32 6 0 4 0 15 EB FL12 11 93...

Страница 9: ...eature the following o NEMA 4 Enclosure o Status lights Green System OK RED System Trouble o Terminals for Microswitch o Intrinsic circuit with barrier and physical separation o Drawings o 120VAC Inpu...

Страница 10: ...counterweights Sizes 12 thru 28 have 1 counter weight Sizes 32 Utilize 2 counterweights with patented breaking elements Dependent on the size of the No Return valve the O EM NRV CP02 control panel O...

Страница 11: ...AL MANUAL V2016NRV ELE ASSEMBLY INSTRUCTIONS SIZES 7 10 No Return Valve Sizes 7 10 have a locking arm without a counterweight and come assembled as shown in the above picture For mounting the microswi...

Страница 12: ...Page 12 of 28 EM NRV NORTH AMERICAN SUPPLEMENTAL MANUAL V2016NRV ELE ASSEMBLY INSTRUCTIONS SIZES 12 28 Counter Weight Locking Mechanism Manual with Metric Allen Wrench...

Страница 13: ...ensor refer to pages 18 22 Replace Bolt on Counter Weight Mounting Shaft Remove Bolt on Counter Weight Mounting Shaft Using Provided Allen Wrench Position Counter Weight in the Locked Position in the...

Страница 14: ...NRV NORTH AMERICAN SUPPLEMENTAL MANUAL V2016NRV ELE ASSEMBLY INSTRUCTIONS SIZES 32 Manual with Metric Allen Wrenches Locking Mechanism Counter Weight Arm Lower Section Breaking Elements Counter Weigh...

Страница 15: ...ection NOTE Lower Section may be Installed at Factory and This Step May not be Necessary Slide Arm until it Fits over the Key Stop Secure Arm in Place by Tightening the Set Screw NOTE You Will Need to...

Страница 16: ...the EcoMAXX NRV 2 Ensure handle is centered in the locking mechanism If incorrectly installed handle may rub or stick preventing the counter weight from locking in place during an event 5 Insert safe...

Страница 17: ...place remove breaking element bolts 8 Mount breaking element to counter weight and tighten bolts Do not over tighten Bolts need to be snug Over tightening may damage breaking element IMPORTANT Be sur...

Страница 18: ...18 of 28 EM NRV NORTH AMERICAN SUPPLEMENTAL MANUAL V2016NRV ELE O EM NRV MS Microswitch with Mounting Bolts 1 Remove screw and rotate lever to correct position 2 Line up arrows 3 Insert and tighten S...

Страница 19: ...echanism using provided bolts 2 Rotate counterweight arm into the locked position Ensure arm is centered in the locking mechanism to avoid obstruction or rubbing If not centered the arm may not fully...

Страница 20: ...EM NRV MS Microswitch to O EM NRV CP02 Intrinsic Panel 1 When looking at the wiring diagram you will notice only the black and grey wires are used for the microswitch connection 2 Connect the black wi...

Страница 21: ...ting nut on sensor and adjust to required height described in drawing provided Tighten mounting nut to secure in place 1 Remove bolt on bottom side of the EcoMAXX No Return Valve NRV 2 Install first m...

Страница 22: ...NRV CP02 Intrinsic Panel 1 On the Wiring diagram you will notice the Dust Level Sensor will be installed inside the physical barrier in the control panel 2 Connect brown wire to the terminal labeled...

Страница 23: ...system control panel You will need to refer to your Main system wiring diagram to determine how the connection needs to be made 2 Connect low voltage control wire to terminal 3 Run wire to main syste...

Страница 24: ...AL MANUAL V2016NRV ELE Wiring the EcoMAXX O EM NRV CP02 Intrinsic Panel to your Main System Control Panel OPTION 2 1 Connect the low voltage control wire to the 3 and 6 terminals as described in optio...

Страница 25: ...NRV NORTH AMERICAN SUPPLEMENTAL MANUAL V2016NRV ELE Wiring 120VAC Supply Power to the EcoMAXX O EM NRV CP02 Intrinsic Panel 1 120 1 60 supply power is required to power the panel Connect to terminals...

Страница 26: ...Page 26 of 28 EM NRV NORTH AMERICAN SUPPLEMENTAL MANUAL V2016NRV ELE General Wiring Diagram for the EcoMAXX O EM NRV CP02 Intrinsic Panel...

Страница 27: ...ith Mounting Bracket P N RP EM NRV LMB Flanges and Co Flanges Flange P N EB FL Co Flange P N EB CFL Breaking Element P N RP EM NRV BE Microswitch P N O EM NRV MS Dust Level Sensor P N O EM NRV DLS Con...

Страница 28: ...UPPLEMENTAL MANUAL V2016NRV ELE FIRE AND EXPLOSION PROTECTION SYSTEMS P O BOX 953 33100 NE IVY AVENUE LA CENTER WA 98629 USA PH 360 263 2360 FAX 360 263 9772 INFO BOSSPRODUCTSAMERICA COM WWW BOSSPRODU...

Отзывы: