Troubleshooting Guide
88
PROBLEM
DIAGNOSTIC CHECK
RESULT
3. Plow will not lower.
Check power/ground cables
and control cables are
connected properly.
Connect.
Check flow control valve.
If flow control valve is
completely closed, place
RAISE/LOWER switch in
NEUTRAL, then open the flow
control valve.
Check wiring on valve block
for proper connections.
Refer to the wiring diagram in
your Installation manual.
Check for voltage between
solenoid valve terminal and
ground with ignition switch
on and control switch in
FLOAT position.
If voltage is present solenoid
valve or valve coil has failed.
Replace valve or valve coil.
Test power to the control box
by checking voltage between
black wire and ground at the
white 9-pin connector.
If NO voltage is present,
power from relays has become
disconnected. If voltage is
present, check wiring and
switch of controller.
Содержание MSC08042C
Страница 8: ...Power V Recommended Push Beam Height 9 Figure 1 Recommended Power V Push Beam Height G10364 ...
Страница 10: ...Power V Mounting Instructions 11 Figure 4 Snowplow Mounting Instructions G10349 ...
Страница 11: ...Power V Removal Instructions 12 Figure 5 Snowplow Removal Instructions G10350 ...
Страница 16: ...Power V Controllers 17 Control Operating Instructions Figure 8 Power V Control Instructions G10365 ...
Страница 43: ...Recommended Straight Blade Push Beam Height 44 Figure 21 Recommended Straight Blade Push Beam Height G10155 ...
Страница 44: ...Recommended Sport Duty Push Beam Height 45 Figure 22 Recommended Sport Duty Push Beam Height G10299 ...
Страница 45: ...Coupler Spring Pin Caution 46 Figure 23 Spring Pin Caution ...
Страница 46: ...Straight Blade Mounting Instructions 47 Figure 24 Snowplow Mounting Instructions G10351 ...
Страница 47: ...Straight Blade Removal Instructions 48 Figure 25 Snowplow Removal Instructions G10352 ...