6 720 607 800 (2016/02)
18 | Electrical connection
7
Electrical connection
The appliance is provided with a labelled feed cable. All
regulation, verification and safety mechanisms have been
rigorously tested in the factory and are ready for use.
7.1
Connection
▶ Connect the feed cable to an earthed power point.
7.2
Power cable
The appliance is provided with a labelled power cord and
earthed mains plug. All regulation, verification and safety
mechanisms have been rigorously tested in the factory and are
ready for use.
▶ Connect the power cable to an earthed socket.
Fig. 16
Power cable connections
8
Gas regulation
8.1
Factory regulations
Natural gas
Heaters designed for Natural gas H (G 20) are factory sealed for
delivery after the values on the characteristics panel have been
checked.
Liquid gas
Propano/butane heaters (G31/G30) are factory sealed for
delivery after the values on the characteristics panel have been
checked.
Power may be tuned according to the burner pressure process,
for which a manometer with U-shaped connecting tubes is
required.
DANGER:
Electrical discharge!
▶ Before working on the electrical
installation, always disconnect the
electrical current.
CAUTION:
Storms
▶ The appliance should have an
independent connection to the
electricity mains, protected by a
differential 30 mA switch and be
earthed. In areas subject to frequent
storms, a storm protector should be
installed.
The electrical connection should be
according to current regulations regarding
domestic electrical installations.
If the power cable gets damaged it must be
replaced by a genuine spare part.
Sealed parts must not be interfered with.
Heaters should not be ignited when the
coupling pressure is less than 15 mbar more
than 25 mbar.
DANGER:
▶ The following operations must be
carried out by a qualified technician.
6720680323-01.1Av