Pre-installation requirements
6 720 808 928 (2017/06)
21
4.7.2
Unmixed central heating with under-floor
Fig. 16
Option 1: Control of under-floor with Sense II (EMS controller)
example
Fig. 17
Option 2: Control of under-floor with 230V programmable room
thermostat example
Fig. 18
Connections/
Symbol
Function
Limiter thermostat (under-floor safety cut-off)
• Potential free
Sense II connection
• EMS2 Room control
– Not polarity sensitive
Outdoor temperature sensor
• Not polarity sensitive
6720808928-40.1W
o
T
6720808928-50.1W
o
LR
L
EMS
2
1
2
1
Connections/
Symbol
Function
Limiter thermostat (under-floor safety cut-off)
• Potential free
230 V feed to external time and temperature
control
• 230V programmable room thermostat
– Switch live demand input [LR]
– Live output [L]
– Neutral output [N]
– Earth output [
]
6720808928-52.1W
o
LR
L
120/230 VAC
N
LR
L
LR
L
120/230 VAC
N