Cleaning and maintenance
en
43
Descaling
Descaling should not be necessary if
the detergent is measured out correctly.
However, if it is required, follow the
manufacturer's instructions for the
descaling agent. Suitable descalers can
be obtained via our website or from
customer services.
Drain pump is blocked
Note:
Turn the water tap off to prevent
more water from flowing in and to
ensure that it is drained via the pump.
:
Warning
Risk of scalding!
When you wash at high temperatures,
the water gets very hot. If you come into
contact with the hot water, you may be
scalded.
Allow the water to cool down first.
1.
Turn the programme selector to
Off
.
Pull out the mains plug.
2.
Open the service flap.
3.
Take the drain hose out of the
retainer.
Remove the sealing cap and pour
the water out into a suitable
container.
Replace the sealing cap and place
the drain hose back in the retainer.
4.
Carefully unscrew the pump cover;
residual water may leak out.
Clean the interior, pump cover
thread and pump housing. The
impeller in the drain pump must be
able to rotate.
5.
Refit and screw on the pump cover.
The handle must be in a vertical
position.