en
Troubleshooting
40
Fault
Cause and troubleshooting
flashes.
Voltage under-usage may cause extension of a pro-
gramme.
No remedial action possible.
lights up.
The temperature is too high.
▶
Wait until the temperature has dropped.
▶
"Cancelling the programme", Page 30
Water level is too high.
▶
Select a suitable programme for draining.
→
flashes.
Door is not closed.
▶
Close the door.
Laundry is caught in the door.
▶
Remove any trapped laundry.
All other error codes.
Malfunction
▶
Call the after-sales service.
→
"E:30/-20"
Solenoid valve defective.
▶
Call the after-sales service.
→
Detergent dosage is too high.
▶
Reduce the amount of detergent for the next wash-
ing cycle with the same load.
Additional water is added.
▶
Do not add any extra water to the appliance while it
is operating.
The appliance is not
working.
The mains plug of the power cord is not plugged in.
▶
Connect the appliance to the power supply.
The circuit breaker in the fuse box has tripped.
▶
Check the circuit breaker in the fuse box.
There has been a power cut.
▶
Check whether the lighting in your kitchen or other
appliances are working.
The programme does
not start.
You have not pressed
.
▶
Press
.
Door is not closed.
1.
Close the door.
2.
Press
to start the programme.
Childproof lock is activated.
▶
Содержание WGG2540ESN