en
Installation and connection
16
Siphon
Secure the con-
nection point with
a (24–40 mm)
hose clamp.
Sink
Fix and secure
the water outlet
hose with an el-
bow.
Plastic pipe with
rubber sleeve or
gully
Fix and secure
the water outlet
hose with an el-
bow.
4.7 Aligning the appliance
In order to reduce noise and vibra-
tion and to prevent the appliance
from moving, align the appliance cor-
rectly.
1.
Loosen the lock nuts using a WAF
17 wrench by turning it in a clock-
wise direction.
2.
To align the appliance, turn the ap-
pliance feet. Check that the appli-
ance is level using a spirit level.
All appliance feet must stand firmly
on the ground.
3.
Screw the lock nuts tightly against
the housing using a WAF 17
wrench.
In doing so, hold the foot tight and
do not adjust its height.
4.8 Connecting the appliance
to the electricity supply
Note:
Your electrical domestic install-
ation for this appliance must comply
with the local legal provisions and
safety regulations, and should in-
clude a residual current circuit-
breaker.
1.
Insert the mains plug of the appli-
ance's power cable in a socket
nearby.