BISN0047.0
26/06/2007 Page 3
Characteristic Data
Pilot orifice diameter (mm)
NG
0.30
LPG
0.19
TG
0.56
TLP
0.56
Burner injector diameter (mm)
NG
1.20
LPG
0.75
TG
2.15
TLP
2.15
Burner pressure ( kPa )
NG
0.87
LPG
2.60
TG
0.40
TLP
0.40
Water flow selector at left hand stop.
Maximum water flow
10 litres / minute
Temperature rise
25°C
Minimum inlet pressure
NG
90 kPa
( 9.0 metres W.G.)
LP
55 kPa
( 5.5 metres W.G.)
Water flow selector at right hand stop
Minimum water flow
4.5 litres / minute
Temperature rise
55°C
Minimum inlet pressure
NG
30 kPa
( 3 metres W.G. )
LP
10 kPa
( 1 metre W.G. )
Refer to rating label located on the bottom right hand corner of the back panel for additional
data.
Freezing
Weather
In areas where the atmospheric temperature may drop below 0°C,
the heater must be drained to prevent damage by expansion of freezing
water. For appliances installed in locations where the temperature falls
below 0° C for brief periods , the installation of an EXOGEL expansion
valve, (part number H 707 060 151), will minimise the possibility of damage
to the appliance.
This water heater
MUST NOT
be installed in areas where the
temperature remains below 0°C for extended periods.
Conversion and Spare Parts
For spare parts or conversion of the heater to operate on a different gas that for which it was
originally manufactured, please contact your local gas authority, authorised service agent or
the manufacturer
Exogel
Hot Water
1 Metre
minimum