en
Cleaning and servicing
50
Cleaning the drain pump
Note:
Please read the information in
the Safety →
sections
to ensure that you use the appliance
safely.
Requirement:
1.
Since water may remain in the
drain pump, remove the pump cap
carefully.
2.
Clean the interior, the thread on
the pump cap and the pump hous-
ing.
3.
Make sure that the impeller in the
drain pump can be rotated.
4.
Insert the maintenance flap and
lock it into place.
5.
Close the maintenance flap.
17.6 Cleaning the water outlet
hose at the siphon
1.
Switch off the appliance.
2.
Disconnect the appliance's mains
plug from the power supply.
3.
Loosen the hose clamp and care-
fully remove the water outlet hose.
Residual water may leak out.
4.
Clean the water outlet hose and si-
phon connecting piece.