![Bosch VG4 Series Скачать руководство пользователя страница 88](http://html.mh-extra.com/html/bosch/vg4-series/vg4-series_installation-manual_46466088.webp)
88
en | Cable and Wire Standards
VG4 Modular Camera Series
F.01U.216.010 | 8.0 | 2011.02
Installation Manual
Bosch Security Systems, Inc.
5
Cable and Wire Standards
5.1
Power
5.2
Wire Distance Guide for Pendant
Table 5.1
Maximum Wire Distances from Power Supply to AutoDome Pendant
115/230 VAC
Copper Wire
To comply with local codes.
24 V to AutoDome
INDOOR ANALOG
VA / Watts
14 AWG (2.5 mm) 16 AWG (1.5 mm) 18 AWG (1.0 mm)
100 Series
14 /7.5
248 m (813 ft)
156 m (512 ft)
98 m (322 ft)
200, 300 Series
18 / 10
193 m (632 ft)
121 m (398 ft)
76 m (250 ft)
500 Series
27 / 15
129 m (422 ft)
81 m (265 ft)
51 m (167 ft)
INDOOR ETHERNET
VA / Watts
14 AWG (2.5 mm) 16 AWG (1.5 mm) 18 AWG (1.0 mm)
100 Series
21 / 11.5
165 m (542 ft)
104 m (341 ft)
65 m (215 ft)
200, 300 Series
25 / 14
139 m (455 ft)
87 m (287 ft)
55 m (180 ft)
500 Series
35 /19
99 m (325 ft)
62 m (205 ft)
39 m (129 ft)
OUTDOOR ANALOG
1
VA / Watts
14 AWG (2.5 mm) 16 AWG (1.5 mm) 18 AWG (1.0 mm)
100 Series
47 / 43.5
74 m (242 ft)
46 m (152 ft)
29 m (96 ft)
200, 300 Series
50 / 46
69 m (228 ft)
44 m (143 ft)
27 m (90 ft)
500 Series
55 / 51
63 m (207 ft)
40 m (130 ft)
25 m (82 ft)
OUTDOOR ETHERNET
1
VA / Watts
14 AWG (2.5 mm) 16 AWG (1.5 mm) 18 AWG (1.0 mm)
100 Series
52 / 47.5
67 m (219 ft)
42 m (138 ft)
26 m (87 ft)
200, 300 Series
54 / 50
64 m (211 ft)
40 m (133 ft)
25 m (83 ft)
500 Series
60 / 55
58 m (190 ft)
36 m (119 ft)
23 m (75 ft)
1. Standard heater module