![Bosch VG4 Series Скачать руководство пользователя страница 60](http://html.mh-extra.com/html/bosch/vg4-series/vg4-series_installation-manual_46466060.webp)
60
en | Installing Roof Parapet and Pipe Mounts
VG4 Modular Camera Series
F.01U.216.010 | 8.0 | 2011.02
Installation Manual
Bosch Security Systems, Inc.
3.7.1
Wiring for Multiple AutoDomes
To wire multiple AutoDomes in a series, or “daisy chaining,” you must apply a terminating
resistor to the last dome of the series. The Interface Board is supplied with a 100
?
terminating resistor located between the Biphase terminals C- and C+ (pins 1 and 2) of the
P105 control connector (see item 5 in
Figure 3.10
above). Remove the resistor from all but the
last AutoDome Interface Board. The maximum number of AutoDomes that can be daisy
chained is four (4).If using the RS485 protocol for control, switch the terminating resistor
from the Biphase C+ and C- terminals to the RxD+ and TxD- terminals (pins 4 and 5) of the
P105 control connector for the last dome (see item 6 in
Figure 3.10
above).
3.7.2
Connecting Wires to the Pipe Interface Board
The Pipe Interface Board contains all of the connectors for control, data, image, and power
wires. Follow the procedures below to make the proper connections.
1.
Attach a BNC connector to the video coax cable and connect it to its mating connector
J102 on the Pipe Interface Board. If using UTP for video or Ethernet, attach an RJ45
connector plug to the e UTP cable and connect the plug to its mating connector J101 on
the Pipe Interface Board.
Ref. Description
Connector
Wire Gauge
Pin
Description
1
Pipe Interface Module
2
Video Coax In
J102
3
6-pin Connector Alarms In (3-7)
P103
4
4-pin Connector Alarms Out (1-3)
P102
5
100
?
Resistor
P105
6
Data In/Out
P105
AWG 26-16
1
Biphase (C-)
2
Biphase (C+)
3
Earth Ground
4
RxD +
5
TxD -
6
Signal Ground
7
Alarms In (EOLR Supervised, 1-2)
P104
AWG 26-16
7
Ground
6
Alarm 2
5
Alarm 1
4
Earth Ground
8
Relay Output
P104
AWG 26-16
3
Normally Closed
2
Common
1
Normally Open
9
Dome Power
P101
AWG 18-14
3
Dome 24 VAC
2
Earth Ground
1
Dome 24 VAC
10
Heater Power
P107
AWG 18-14
2
Heater 24 VAC
1
Heater 24 VAC
11
RJ45 Ethernet or UTP Video
J101
12
To AutoDome
WARNING!
Use a 24 VAC Class 2 power supply only.
WARNING!
Do not connect the RJ45 connector unless using UTP video or Ethernet. This connection
causes video distortion.