13 | Online Measurement and Calibration
76 / 136
Vehicle_Control_Unit_VCU_Manual
Bosch Motorsport
Check box to enable online
offset calibration and enter
desired physical target value
In the channel view
Activate switch
to enable online
calibration
13.2.2 Performing the online offset calibration
Vehicle Control Unit VCU has to be connected to RaceCon to calibrate the sensor’s offset.
1.
Apply the desired physical condition to the sensor (e.g. 1 G to an acceleration sensor).
2.
Open the measurement channel’s online page by double-clicking on the measure-
ment channel name in the Data Area.
3.
Enter the physical target value (e.g. 1 G) and press the ‘Calibrate’ button.
Calibration
target value
Initiate
calibration
The sensor’s offset is now calibrated.
Содержание VCU
Страница 1: ...Vehicle Control Unit VCU Manual Version 1 3 02 07 2020 ...
Страница 90: ...14 Recording 90 136 Vehicle_Control_Unit_VCU_Manual Bosch Motorsport ...
Страница 133: ...Bosch Motorsport Vehicle_Control_Unit_VCU_Manual 133 136 ...
Страница 134: ...134 136 Vehicle_Control_Unit_VCU_Manual Bosch Motorsport ...
Страница 135: ...Bosch Motorsport Vehicle_Control_Unit_VCU_Manual 135 136 ...
Страница 136: ...Bosch Engineering GmbH Motorsport Robert Bosch Allee 1 74232 Abstatt Germany www bosch motorsport com ...