11 | Analog and Frequency Inputs
54 / 136
Vehicle_Control_Unit_VCU_Manual
Bosch Motorsport
Input pin Pull-up
resistor is
activated
Sensivity and
Offset value
for sensor
Adjustment
is enabled
Channel is linked
to ANA04
Pin Diagnosis
Name and
Description
editable
Available measurements for channel:
Measurement label
Function
raw_
name
mV value of sensor
raw_
name
_fi
filtered mV value of sensor
name
physical value of sensor
name
_fi
filtered physical value
11.2.3 Configuring a generic nonlinear sensor
Example: Thermistor 5 kOhm
– From sensor data sheet - resistance values over temperature:
– The sensor has a nonlinear behavior
– Use characteristic curve for linearization
– Input voltage is the ratio between pull-up resistor and thermistor
Pin
Thermistor
+5V
3 kOhm
1.
Click ‘Measurement Sources’ in the Toolbox.
2.
To expand the list of ‘I/O Channels’, click on ‘+’ in the Vehicle Control Unit VCU Pro-
ject Tree.
3.
Drag the “Characteristic Curve” analogue signal source from the Toolbox and drop it
on the desired analogue input channel in the Vehicle Control Unit VCU Project Tree.
Содержание VCU
Страница 1: ...Vehicle Control Unit VCU Manual Version 1 3 02 07 2020 ...
Страница 90: ...14 Recording 90 136 Vehicle_Control_Unit_VCU_Manual Bosch Motorsport ...
Страница 133: ...Bosch Motorsport Vehicle_Control_Unit_VCU_Manual 133 136 ...
Страница 134: ...134 136 Vehicle_Control_Unit_VCU_Manual Bosch Motorsport ...
Страница 135: ...Bosch Motorsport Vehicle_Control_Unit_VCU_Manual 135 136 ...
Страница 136: ...Bosch Engineering GmbH Motorsport Robert Bosch Allee 1 74232 Abstatt Germany www bosch motorsport com ...