12
|
Technical description
UNIMAT
6 720 807 794 (2013/04)
3.3
Dimensions and specification for the flue
gas heat exchangers
3.3.1
UNIMAT UT-L boiler
Fig. 8
UNIMAT UT-L boiler
51.002
Optional instrument housing
51.004
Optional terminal box
A01.000 Optional burner
D03.000 Flue gas connecting branch
D04.000 Boiler front door
D05.002 Inspection aperture on the flue gas side
D05.005 Flame inspection hole
D06.000 Base frame
D06.002 Lifting lug
D07.000 Optional maintenance platform
D08.000 Optional positive pressure safety valve 1
D08.100 Optional positive pressure safety valve 2
D10.000 Flow
D10.002 Optional intermediate flow piece
D11.000 Return
D12.001 Optional outlet shut-off valve
D12.503 Connection for flue gas condensate drainage
system
6 720 803 977-11.1itl
D07.000
D03.000
D12.503
D05.002
A01.000
D04.000
D06.000
D12.001
D05.005
51.004
D08.100
D11.000
D08.000
D06.002
D10.000
51.002
D10.002
UNIMAT
UT-L boiler
Output limit
Dimension(s)
Flue gas
connection
Base frame
L1
1)
L2
L3
B1
H1
2)
H2
H3
3)
H4
L4
B2
H5
Channel
section
Type
kW
[mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm]
[mm]
[mm] [mm]
[mm]
UT-L 1
650
3135 2295 2040 1174 2152 1540 1460 1055
1750
710
120
1055
UT-L 2
750
3516 2680 2425 1324 2302 1695 1610 1180
2100
910
120
1180
UT-L 4
1000
3516 2680 2425 1324 2302 1695 1610 1180
2100
910
120
1180
UT-L 6
1000
3786 2950 2695 1424 2402 1795 1710 1240
2350
910
120
1240
UT-L 8
1250
4056 3220 2960 1524 2502 1895 1810 1340
2560
930
160
1340
UT-L 10
1350
3778 2950 2695 1424 2402 1795 1710 1240
2350
910
120
1240
UT-L 12
1500
4503 3675 3420 1574 2552 1950 1860 1350
3060
1130
160
1350
UT-L 14
1900
4092 3220 2960 1524 2502 1895 1810 1340
2560
930
160
1340
UT-L 16
2000
4597 3725 3465 1674 2652 2050 1960 1415
3060
1130
160
1415
UT-L 18
2500
4654 3675 3420 1574 2552 1950 1860 1350
3060
1130
160
1350
UT-L 20
2500
5054 4075 3820 1724 2702 2100 2010 1490
3410
1150
200
1490
UT-L 22
3000
5895 4570 4250 1824 2817 2200 2110 1500
3920
1260
220
1500
UT-L 24
3050
4916 3725 3465 1674 2667 2050 1960 1415
3060
1130
160
1415
UT-L 26
3500
6025 4700 4380 1924 2917 2300 2210 1600
3920
1510
220
1600
UT-L 28
3700
5266 4075 3820 1724 2717 2100 2010 1490
3410
1150
200
1490
UT-L 30
4200
5761 4570 4250 1824 2817 2200 2110 1500
3920
1260
220
1500
UT-L 32
4250
6419 5090 4770 2124 3117 2505 2410 1750
4280
1510
220
1750
UT-L 34
5200
6385 4700 4380 1924 3007 2300 2210 1600
3920
1510
220
1600
Table 4 Main dimensions