background image

High Performance LCD Monitors

Safety | en

1

Bosch Security Systems, Inc.

User’s Manual

F.01U.075.713 | 1.0 | 2008.03

1

Safety

1.1

Important Safety Instructions

Read, follow, and retain for future reference all of the following safety instructions. Heed all 

warnings on the unit and in the operating instructions before operating the unit.

1.

Cleaning - 

Unplug the unit from the outlet before cleaning. Follow any instructions 

provided with the unit. Generally, using a dry cloth for cleaning is sufficient, but a moist 

fluff-free cloth or leather shammy may also be used. Do not use liquid cleaners or aerosol 

cleaners.

2.

Heat Sources - 

Do not install the unit near any heat sources such as radiators, heaters, 

stoves, or other equipment (including amplifiers) that produce heat.

3.

Ventilation -

 Any openings in the unit enclosure are provided for ventilation to prevent 

overheating and ensure reliable operation. Do not block or cover these openings. Do not 

place the unit in an enclosure unless proper ventilation is provided, or the manufacturer's 

instructions have been adhered to.

4.

Water - 

Do not use this unit near water, for example near a bathtub, washbowl, sink, 

laundry basket, in a damp or wet basement, near a swimming pool, in an outdoor 

installation, or in any area classified as a wet location. To reduce the risk of fire or 

electrical shock, do not expose this unit to rain or moisture.

5.

Object and liquid entry - 

Never push objects of any kind into this unit through openings 

as they may touch dangerous voltage points or short-out parts that could result in a fire 

or electrical shock. Never spill liquid of any kind on the unit. Do not place objects filled 

with liquids, such as vases or cups, on the unit.

6.

Lightning - 

For added protection during a lightning storm, or when leaving this unit 

unattended and unused for long periods, unplug the unit from the wall outlet and 

disconnect the cable system. This will prevent damage to the unit from lightning and 

power line surges.

7.

Controls adjustment -

 Adjust only those controls specified in the operating instructions. 

Improper adjustment of other controls may cause damage to the unit. Use of controls or 

adjustments, or performance of procedures other than those specified, may result in 

hazardous radiation exposure.

8.

Overloading - 

Do not overload outlets and extension cords. This can cause fire or 

electrical shock.

9.

Power cord and plug protection - 

Protect the plug and power cord from foot traffic, 

being pinched by items placed upon or against them at electrical outlets, and its exit 

from the unit. For units intended to operate with 230 VAC, 50 Hz, the input and output 

power cord must comply with the latest versions of 

IEC Publication 227

 or 

IEC Publication 

245

.

10.

Power disconnect - 

Units with or without ON/OFF switches have power supplied to the 

unit whenever the power cord is inserted into the power source; however, the unit is 

operational only when the ON/OFF switch is in the ON position. The power cord is the 

main power disconnect device for switching off the voltage for all units.

Содержание UML-150-90

Страница 1: ...General Purpose LCD Monitors UML 150 90 UML 170 90 UML 190 90 en User s Manual ...

Страница 2: ......

Страница 3: ... 2 Mounting the Monitor 12 5 2 1 Desktop Installation 12 5 2 2 Wall Mount Installation 13 5 3 Connecting the Composite Video Signal to the Monitor 14 5 4 Connecting the Y C S Video Signal to the Monitor 14 5 5 Connecting the PC Signal to the Monitor 14 5 6 Single Multiple Monitor Configuration 15 6 Navigating the Monitor 16 6 1 Navigating the Front Panel 16 6 2 Navigating the Monitor On screen Dis...

Страница 4: ...iv en Table of Contents General Purpose LCD Monitors F 01U 078 454 1 0 2008 03 User s Manual Bosch Security Systems Inc 8 Trouble Shooting Guide 22 9 Maintenance 22 10 Technical Specifications 24 ...

Страница 5: ...ects of any kind into this unit through openings as they may touch dangerous voltage points or short out parts that could result in a fire or electrical shock Never spill liquid of any kind on the unit Do not place objects filled with liquids such as vases or cups on the unit 6 Lightning For added protection during a lightning storm or when leaving this unit unattended and unused for long periods ...

Страница 6: ...ing service Unplug the unit from the main AC power source and refer servicing to qualified service personnel when any damage to the equipment has occurred such as the power supply cord or plug is damaged exposure to moisture water and or inclement weather rain snow etc liquid has been spilled in or on the equipment an object has fallen into the unit unit has been dropped or the unit cabinet is dam...

Страница 7: ...IEC60950 Any output or signal lines from the camera must be SELV or Limited Power Source For safety reasons the environmental specification of the camera lens assembly must be within the environmental specification of 10 C 14 F to 50 C 122 F Camera signal Protect the cable with a primary protector if the camera signal is beyond 140 feet in accordance with NEC800 CEC Section 60 Coax grounding Groun...

Страница 8: ...rotection must be secured with a maximum fuse rating of 16A This must be in accordance with NEC800 CEC Section 60 Grounding and polarization This unit may be equipped with a polarized alternating current line plug a plug with one blade wider than the other blade This safety feature allows the plug to fit into the power outlet in only one way If unable to insert the plug fully into the outlet conta...

Страница 9: ...is equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules and ICES 003 of Industry Canada These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and radiates radio frequency energy and if not installed and...

Страница 10: ... fédérale des communications FCC peut s avérer utile How to Identify and Resolve Radio TV Interference Problems Comment identifier et résoudre les problèmes d interférences de radio et de télévision Cette brochure est disponible auprès du U S Government Printing Office Washington DC 20402 États Unis sous la référence n 004 000 00345 4 AVERTISSEMENT Ce produit est un appareil de Classe A Son utilis...

Страница 11: ... to be registered trademarks and must be treated accordingly i NOTICE This user guide has been compiled with great care and the information it contains has been thoroughly verified The text was complete and correct at the time of printing The ongoing development of the products may mean that the content of the user guide can change without notice Bosch Security Systems accepts no liability for dam...

Страница 12: ... Telephone 888 289 0096 Fax 585 223 9180 Email security sales us bosch com Technical Support Telephone 800 326 1450 Fax 585 223 3508 or 717 735 6560 Email technical support us bosch com Repair Center Telephone 585 421 4220 Fax 585 223 9180 or 717 735 6561 Email security repair us bosch com Canada Telephone 514 738 2434 Fax 514 738 8480 Europe Middle East Asia Pacific Region Telephone 44 0 1495 274...

Страница 13: ...iginal packing carton is the safest container in which to transport the unit and must be used if returning the unit for service Save it for possible future use 2 1 Parts List The following table lists the parts included Quantity Part 1 UML 150 90 UML 170 90 or UML 190 90 Color LCD Flat Panel Monitor 1 Installation manual 2 Power Cords 3 wire with grounded plug 1 8 m 6 ft long one with a U S plug t...

Страница 14: ...1 AV2 or S Video 2 Menu Button Selects the on screen display OSD 3 S Adjusts the value when in the OSD Scrolls up in the OSD 4 T Adjusts the value when in the OSD or auto adjusts when in PC mode Scrolls down in the OSD 5 W Decreases the value when in the OSD Scrolls left in the OSD 6 X Increases the value when in the OSD Scrolls right in the OSD 7 Not Used 8 Power Button LED Indicator Power On gre...

Страница 15: ...dition each works with a VGA signal Monitor control functions are accessed via the front panel push buttons and the multi language On screen Display OSD See Figure 3 1 for front panel descriptions Reference Connector Description 1 DC 12 V IN UML 150 50 3 3 A UML 170 50 4 1 A UML 190 90 4 1 A 2 D SUB IN PC Signal Input 3 VIDEO 1 AV1 IN Composite signal input for AV1 4 VIDEO 1 AV1 OUT Video looping ...

Страница 16: ...l the monitor and adhere to all local codes 5 1 Ventilation To prevent overheating ensure that the ventilation openings on the rear of the monitor are not covered 5 2 Mounting the Monitor The UML 150 90 UML 170 90 and the UML 190 90 are designed for use on a desktop or mounted to a wall or rack 5 2 1 Desktop Installation The Bosch General Purpose monitors are delivered with a 3 pole US style power...

Страница 17: ... the UMM LW 30B swivel tilt To install the wall mount do the following 1 Remove the base from the LCD panel section by unscrewing the four 4 holding screws before separating the base from the panel NOTE Save screws for future use Figure 5 1 Removing the Base 2 Mount the unit to the mounting device not provided using the four 4 mounting holes on the rear panel The square mounting hole patterns are ...

Страница 18: ...nected to the output connector the video signal can be passed on to another monitor connected to it via the active loop through function Up to three 3 monitors may be connected in this manner see Figure 5 6 5 4 Connecting the Y C S Video Signal to the Monitor There is one 1 mini DIN type connector for the S Video Y C input see Figure 5 3 NOTE Both Y and C inputs are terminated with 75 ohm Figure 5...

Страница 19: ... F 01U 078 454 1 0 2008 03 5 6 Single Multiple Monitor Configuration Figure 5 5 Single Monitor Configuration Figure 5 6 Multiple Monitor Configuration Reference Description 1 Video Camera 2 VIDEO 1 AV1 IN 3 VIDEO 1 AV1 OUT 4 VCR Reference Description 1 Video Camera 2 VIDEO 1 AV1 IN 3 VIDEO 1 AV1 OUT ...

Страница 20: ...t up menus follow the steps below 1 Connect the CVBS or VGA cable 2 If required press the Input button until a signal is displayed NOTE Menus are not available without a signal applied 3 Press the Power button to turn on the unit see Figure 3 1 4 Press the Menu button to activate the main menu selections see Figure 3 1 5 Press the Sand the Tbuttons to select a main menu 6 Press the Menu button to ...

Страница 21: ...source Choices are PC AV1 AV2 or S Video Screen Adjusts the Brightness Contrast Saturation Hue and the Sharpness level for video performance of the OSD Audio Not available OSD on screen display Adjusts the H Position V Position Transparency OSD Timer and Language Language choices are English French German Italian Dutch and Spanish Color PC mode Adjusts the color temperature to 9300 6500 or user fa...

Страница 22: ... press the arrows to select the Input Source submenu 6 5 Screen To access the Screen submenu press the Menu button on the front panel of the monitor then press the left and right arrows to select the Screen icon Press the up and down arrows to select the Screen submenu Input Source Move EXIT MENU Screen Brightness Contrast Saturation Sharpness Move EXIT MENU Screen Brightness Contrast H Position V...

Страница 23: ...mance range 0 100 H Position PC mode Adjusts the horizontal position for the desktop range 0 100 V Position PC mode Adjusts the vertical position for the desktop range 0 100 Clock Adjusts the best picture quality by adjusting the horizontal size of the video displayed range 0 100 Phase Adjusts for best picture quality by adjusting for sharpness of vertical lines range 0 100 OSD H Position V Positi...

Страница 24: ... arrows to select the Color icon Press the up and down arrows to select the Color submenu range 0 100 6 9 Utility To access the Utility submenu press the Menu button on the front panel of the monitor then press the left and right arrows to select the Utility icon Press the up and down arrows to select the Utility submenu Color Color Temp Red Green Blue 9300 K 6500 K User Utility Recall Lock Move E...

Страница 25: ...ower saving mode is active when the LED on the control button panel switches from green to amber and normal operation resumes automatically when the input signal is restored The monitor enters an appropriate mode through identifying each of the three modes of the signaling system 7 1 Power Consumption 7 2 LED Indicator The power management feature of the monitor is comprised of four stages On gree...

Страница 26: ...LED lit Check that the Brightness and or Contrast adjustments of the display have not been turned down to minimum levels Check Input Signal message is displayed in PC mode The signal cable should be completely connected to the video card computer The video card should be completely seated in its slot and the computer switched ON Display image is not centered is too small or too large in the PC mod...

Страница 27: ...tems Inc User s Manual F 01U 078 454 1 0 2008 03 Do not use any of the following as a cleaning agent Ketone type materials Ethyl alcohol Ethyl acid Toluene Methyl chloride Ammonia Use of these materials may permanently damage the polarizer due to a chemical reaction ...

Страница 28: ...m 0 01 x 0 01 in 0 294 x 0 294 mm 0 01 x 0 01 in Resolution 1024 x 768 pixels 400 TV lines typical 1280 x 1024 pixels 400 TV lines typical 1280 x 1024 pixels 400 TV lines typical Aspect Ratio 4 3 5 4 5 4 Display Colors 16 2 million colors 16 2 million colors 8 bit interface 16 7 million colors Response Time 12 ms 5 ms 5 ms Backlight Two 2 cold cathode fluorescent tubes rated life 50 000 hours Two ...

Страница 29: ...rsor Power On Off Front Panel Lockout Multiple push button combination On screen Display Video Mode Input Source Screen OSD Utility PC Mode Input Screen OSD Color Utility Indicators LED Power On green Standby amber Unsupported Mode green Power Off red On screen VGA Check input signal Video Flashes AV1 or AV2 when there is a black screen Connectors Video 1 AV1 Composite video two 2 BNC 1 in 1 out V...

Страница 30: ... 15 4 x 7 9 in 382 4 x 330 0 x 58 7 mm 15 1 x 13 0 x 2 3 in 430 x 428 x 200 mm 16 9 x 16 9 x 7 9 in 420 x 374 x 60 mm 16 9 x 14 7 x 2 4 in Weight Monitor with Base Monitor Only 3 7 kg 8 1 lb 2 5 kg 5 6 lb 6 6 kg 14 6 lb 4 1 kg 9 05 lb 7 6 kg 16 9 lb 5 9 kg 13 1 lb Environmental Operating Temperature 0 C to 40 C 32 F to 104 F Storage Temperature 20 C to 60 C 4 F to 140 F Humidity Maximum 90 non con...

Страница 31: ......

Страница 32: ...Security Systems B V P O Box 80002 5600 JB Eindhoven The Netherlands Phone 31 40 2577 284 Fax 31 40 2577 330 emea securitysystems bosch com www boschsecurity com Asia Pacific Bosch Security Systems Pte Ltd 38C Jalan Pemimpin Singapore 577180 Phone 65 6319 3450 Fax 65 6319 3499 apr securitysystems bosch com www boschsecurity com Bosch Security Systems 2008 F 01U 078 454 1 0 2008 03 Data subject to ...

Отзывы: