Incoming power wires
The terminal block accepts wire ranging from 0.5 mm² to 2.5 mm² (20 AWG to 14 AWG). When
using larger wire sizes, splice to a smaller size wire at the terminal block end. The splice may
need to be enclosed in a junction box if it does not pass through the fittings.
1.
Strip no less than 6 mm (0.25 in.) and no more than 8 mm (0.31 in.) of insulation away
from the power supply wires. Do not nick the wires.
2.
Connect the incoming power wires to the AC input connectors (3) on the terminal block
as shown in the following figure:
G
x
L
N
L
AC INPUT
AC OUT
DC12v OUT
N
G
L
N
Callout
Function
1
Power cable input to housing:
- G (green/yellow) Earth wire
- L (blue) power wire
- N (brown) power wire
2
Power input grounding post
3
AC power input terminal block connectors
4
AC power output to camera
5
12 VDC power output to camera
6
Fuse
6.1.2
UHO Camera Housing
Connection | en
17
Bosch Security Systems
Installation Manual
2014.10 | 5.0 | F.01U.167.418