background image

Important safety instructions

Read, follow, and retain for future reference all of the following safety instructions. Follow all
warnings before operating the unit.
1.

Clean only with a dry cloth. Do not use liquid cleaners or aerosol cleaners.

2.

Do not install unit near any heat sources such as radiators, heaters, stoves, or other
equipment (including amplifiers) that produce heat.

3.

Never spill liquid of any kind on the unit.

4.

Take precautions to protect the unit from power and lightning surges.

5.

Adjust only those controls specified in the operating instructions.

6.

Operate the unit only from the type of power source indicated on the label.

7.

Unless qualified, do not attempt to service a damaged unit yourself. Refer all servicing to
qualified service personnel.

8.

Install in accordance with the manufacturer's instructions in accordance with applicable
local codes.

9.

Use only attachments/accessories specified by the manufacturer.

 
Power disconnect - Units have power supplied whenever the power cord is inserted into the
power source. The power cord is the main power disconnect for all units.
 
All-pole power switch Incorporate an all-pole power switch, with a contact separation of at
least 3 mm, into the electrical installation of the building. If it is needed to open the housing,
use this all-pole switch as the main disconnect device for switching off the voltage to the unit.
 
Coax grounding:

Ground the cable system if connecting an outside cable system to the unit.

Connect outdoor equipment to the unit's inputs only after this unit has had its grounding
plug connected to a grounded outlet or its ground terminal is properly connected to a
ground source.

Disconnect the unit's input connectors from outdoor equipment before disconnecting the
grounding plug or grounding terminal.

Follow proper safety precautions such as grounding for any outdoor device connected to
this unit.

Section 810 of the National Electrical Code, ANSI/NFPA No.70, provides information regarding
proper grounding of the mount and supporting structure, grounding of the coax to a discharge
unit, size of grounding conductors, location of discharge unit, connection to grounding
electrodes, and requirements for the grounding electrode.
 

 

1.3

UHO Camera Housing

Safety | en

5

Bosch Security Systems

Installation Manual

2014.10 | 5.0 | F.01U.167.418

Содержание UHO-HBGS

Страница 1: ...UHO Camera Housing UHO HBPS UHO HBGS UHO HGS UHO HPS en Installation Manual ...

Страница 2: ......

Страница 3: ...5 Camera Lens installation 14 5 5 1 Camera tray mount 14 5 5 2 Mounting the camera tray in the housing 15 6 Connection 16 6 1 Feed through power connection 16 6 1 1 Incoming power safety earth connection 16 6 1 2 Incoming power wires 17 6 2 Camera connections 18 6 2 1 Camera video connections 18 6 2 2 Camera power connections 18 6 3 Housings with rear connectors 19 6 3 1 Connection UHO Rear housin...

Страница 4: ...minals when the unit is powered Caution Installation should only be performed by qualified service personnel in accordance with the National Electrical Code NEC 800 CEC Section 60 or applicable local codes Caution This device must be connected to earth ground Safety power ground is indicated by the symbol Caution These units must be properly and securely mounted to a supporting structure capable o...

Страница 5: ...main power disconnect for all units All pole power switch Incorporate an all pole power switch with a contact separation of at least 3 mm into the electrical installation of the building If it is needed to open the housing use this all pole switch as the main disconnect device for switching off the voltage to the unit Coax grounding Ground the cable system if connecting an outside cable system to ...

Страница 6: ...ordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his expense Intentional or unintentional modifications not expressly approved by the party responsible for compliance shall not be made Any such mod...

Страница 7: ...y or indirectly from faults incompleteness or discrepancies between this manual and the product described Trademarks All hardware and software product names used in this document are likely to be registered trademarks and must be treated accordingly More information For more information please contact the nearest Bosch Security Systems location or visit www boschsecurity com 2 UHO Camera Housing S...

Страница 8: ...onnector instead of feed through holes The following models are available Model Input voltage Connection Temperature control UHO HBGS 11 24 VAC Feed through Fan UHO HBGS 51 230 VAC Feed through Fan UHO HBGS 61 115 VAC Feed through Fan UHO HGS 11 24 VAC Feed through Passive UHO HGS 51 230 VAC Feed through Passive UHO HBPS 11 24 VAC Power and BNC connectors Fan UHO HBPS 51 230 VAC Power and BNC conn...

Страница 9: ...2 Washer spring M6 Stainless Steel 3 Plug M4 Silicone UHO HGS AND UHO HBGS models Quantity Item Material 2 Cable gland 3 8 in NPT with locking nut Polyamide neoprene 1 Cable gland 1 2 in NPT with locking nut Polyamide neoprene 1 Cable gland M20 x 1 5 Polyamide neoprene UHO HBPS 11 model Quantity Item Material 1 4 pin cable connector Male ABS UHO HPS 51 and UHO HBPS 51 models Quantity Item Material...

Страница 10: ... Security Systems Sales or Customer Service Representative The original packaging is the safest container in which to transport the unit and can be used if returning the unit for service Tools required Small flat blade screwdriver Phillips screwdriver 1 Adjustable wrench Wire cutter stripper crimper tool 4 2 4 3 10 en Planning information UHO Camera Housing 2014 10 5 0 F 01U 167 418 Installation M...

Страница 11: ...re when selecting mounts or pan tilts not supplied for installation the mounting surface and unit s weight should be carefully considered Camera lens requirements The camera lens combination to be built into the housing must meet the following requirements Maximum power consumption 10 W Maximum weight 1 kg 2 2 lb Maximum size H x W x D 91 x 81 x 262 mm 3 6 x 3 2 x 10 3 in 262 10 3 81 3 2 91 3 6 mm...

Страница 12: ... mounting to all other mounts and pan tilts Opening the cover Caution The heater will be hot when in operation Do not touch Always ensure that the heater is off and cool before working on the camera Open the cover by unlatching the three latches 1 on the side of the housing If the optional tamper resistant screws have been installed use the supplied wrench to remove the screws before opening the l...

Страница 13: ... mount 4 Feed the power and video cables through separate cable glands into the housing 5 Ensure that the holes in the rear are covered with the rubber plugs provided Feed through wiring through the rear The rear holes allow cable to be fed through the supplied glands or the direct connection of conduit fittings 1 Remove the dome plugs located at the rear the housing 2 Screw the cable glands into ...

Страница 14: ...re the camera to the camera tray 1 4 20 x 3 8 in Low profile cameras For low profile camera lens assemblies use different combinations of the 9 mm and the 4 mm plastic spacers to ensure that the camera lens is in the center of the window With the spacers use the 1 4 20 x 3 4 in screw the spring washer and plastic clamp or second spacer as necessary to attach the camera lens to the camera tray 9 mm...

Страница 15: ... side of the housing 2 Lower the tray so that the holes at the side fit over the two screws of the housing 3 Slide the entire assembly forward approximately 5 mm 0 2 in from the front of the window 4 Tighten the two screws to lock the tray in place 2x 5 5 2 UHO Camera Housing Installation en 15 Bosch Security Systems Installation Manual 2014 10 5 0 F 01U 167 418 ...

Страница 16: ...ing power safety earth wire to the grounding post on the PCB bracket assembly as follows 1 A terminal lug 4 is provided for connecting the incoming power safety earth wire 2 Remove the nut the washers and the ground wire lug from the grounding post 5 3 Strip the incoming power safety earth wire and crimp into the lug 4 Reattach the ground connections in the order shown 1 Nut 2 Lock washer 3 Flat w...

Страница 17: ...the power supply wires Do not nick the wires 2 Connect the incoming power wires to the AC input connectors 3 on the terminal block as shown in the following figure G x L N L AC INPUT AC OUT DC12v OUT N G L N Callout Function 1 Power cable input to housing G green yellow Earth wire L blue power wire N brown power wire 2 Power input grounding post 3 AC power input terminal block connectors 4 AC powe...

Страница 18: ...on the terminal block 4 to the 24 VAC inputs of the camera For 120 VAC and 230 VAC cameras Cut the power cord coming from the camera making sure that there is enough left to reach the terminal block Strip no less than 6 mm 0 25 in and no more than 8 mm 0 31 in of insulation away from the power supply wires Do not nick the wires Connect the camera power cord wires to the 120VAC OUT or 230VAC OUT co...

Страница 19: ... must be between 6 mm 0 24 in and 12 mm 0 47 in 2 Strip no less than 6 mm 0 24 in and no more than 8 mm 0 32 in of insulation away from the wire Do not nick the wires 3 Insert the power cord through the back shell assembly and strain relief 4 The cable connector terminals accept wire ranging from 0 75 mm to 2 5 mm 18 AWG to 14 AWG 5 Connect the power input wires to the numbered screw terminals on ...

Страница 20: ... any excess wire out of the housing and tighten the cable glands The tightening force required is approximately 1 to 1 5 turns past the point where the gland starts to grip the wire Failure to correctly tighten the glands could result in water ingress Ensure that all holes are covered with the rubber plugs provided Close the cover and secure the latches Optional tamper resistant screws are provide...

Страница 21: ...open it 2 Replace the fuse with a fuse that has the same current rating The fuse is a 5 mm x 20 mm slow blow breaking capacity cartridge type fuse 3 Push and twist the fuse holder to close it Camera voltage Fuse rating 24 VAC 4 A 250 VAC 120 VAC 2 A 250 VAC 230 VAC 2 A 250 VAC There is a spare fuse inside the housing 7 7 1 UHO Camera Housing Maintenance en 21 Bosch Security Systems Installation Ma...

Страница 22: ...trical appliances which have reached the end of their working life must be collected and disposed of separately from household waste material Separate collecting systems are usually in place for disused electronic and electrical products Please dispose of these units at an environmentally compatible recycling facility per European Directive 2012 19 EU 8 22 en Decommissioning UHO Camera Housing 201...

Страница 23: ......

Страница 24: ...Bosch Security Systems B V Torenallee 49 5617 BA Eindhoven The Netherlands www boschsecurity com Bosch Security Systems B V 2014 ...

Отзывы: