![Bosch UHI Series Скачать руководство пользователя страница 72](http://html.mh-extra.com/html/bosch/uhi-series/uhi-series_installation-manual_38757072.webp)
72
en | UHO-HBPS-10, -50, and UHO-HPS-50
UHI/UHO Series
F.01U.167.418 | 3.0 | 2010.04
Installation Manual
Bosch Security Systems, Inc.
2.
Insert the power cord through the back shell assembly and
strain relief. See
Figure 6.1
).
Figure 6.1
Mating connector 4-pin assembly
3.
The terminal block provided on these units accepts wire
ranging from 0.5 mm
2
to 2.5 mm
2
(20 AWG to 14 AWG).
When using larger wire sizes, splice to a smaller size wire
at the terminal block end.
4.
Connect the power input cable to the screw terminals on
the provided mating connector. See
Figure 6.1
and
Table 6.1
.
Table 6.1
4-pin wiring connections
1
230 VAC ONLY! Female clamping ring
2
24 VAC ONLY! Male clamping ring
3
Internal strain relief
4
Sealing gasket
5
Metal washer
6
Cable nut
Pin
Function
Harness wire color
1
AC neutral
Blue
2
AC live
Brown
3
No Connection
Do not use
4
Ground
Green/yellow