10
|
Installation
US
6 720 647 088 (2011/09)
4.4
Electrical connections
B
Strip back the insulation on the power wires about 3/
8". Any insulation on the ground should be stripped
back about 3/4".
B
Feed the cable through the cover bottom or backplate
entry grommets, as appropriate.
B
Connect the cables to the terminal block and ground
stud (Fig. 3):
Fig. 3
Cable termination
B
Make sure that all the terminal block screws are
tightened securely. Loose connections can cause
wires to neat up.
B
Make sure that the ground wire is wrapped around its
terminal stud and into the saddle washer. The nut
should be tightened securely.
B
Attach the front cover and tighten the retaining
screws.
Rated
Voltage
(V)
Rated
Current
(A)
Recommend
Wire Size
(AWG)
Model
US12
240
50
6
Table 5
NOTE:
When the Tronic 3000C Pro is not within
sight of the electrical circuit breakers, a
circuit breaker lockout or additional local
means of disconnection for all non
grounded conductors must be provided that
is within sight of the appliance. (REF NEC
422.31)
Rubber
Sleeve
Ground