Installation (only for approved contractors)
Tronic 5000 – 6721830067 (2021/06)
22
5.10.1 Configure the power level
▶ Use jumpers
J2
and
J3
to configure the power level of the
appliance, according to the table below.
Table 6
Configuring the power
If the power of the appliance is changed,
▶ Check which flow limiter should be used (
chapter 10).
5.10.2 Setting maximum temperature
▶ Use Jumpers
J4
and
J5
to set the maximum temperature of
the appliance, according to the table below.
Table 7
Setting maximum temperature
5.10.3 Configuring and installing a Priority Relay
For the appliance to work with a priority electric circuit, a
special priority relay (BZ 45L21) is required. Other types of
priority relays, with the exception of electronic priority relays,
may not work correctly.
Fig. 39
Wiring diagram
▶ Remove Jumper
J1
to activate the Priority Relay mode in
the appliance's electronics system, see table below.
TR... 11/
13
TR... 15/
18/21
TR... 21/
24/27
Jumpers: J2 - J3
13 kW
(Factory
Settings)
21 kW
(Factory
Settings)
27 kW
(Factory
Settings)
11 kW
18 kW
24 kW
15 kW
21 kW
Max. Temperature
Jumpers: J4 - J5
Maximum Temperature 60 °C
(Factory Settings)
Maximum Temperature 53 °C
(EN60335 - if the appliance
supplies water for showering)
Maximum Temperature 48 °C
Maximum Temperature 42 °C
Max. Temperature
Jumpers: J4 - J5