Installation (only for approved contractors)
17
Tronic 5000 – 6721830067 (2021/06)
Fig. 21
The opening of the cable conduit must fit the power cable
perfectly. If the cable conduit is damaged during assembly, the
holes must be covered in a watertight manner.
▶ The cable conduit must be cut according to the diameter of
the power cable.
Fig. 22
▶ Insert the connection cable at least 40 mm inside the
appliance, unless you are using the lower connection site
with individual cables.
▶ Pass the power cable through the cable conduit, ensuring
tightness.
Fig. 23
▶ If the distance between the appliance and the wall is 2-
8 mm, the appliance must be levelled using the upper
mounting fixing.
Fig. 24
If the appliance is not perpendicular to the wall,
▶ Use spacers at the bottom to level the appliance.