6 720 680 174 (2014/05)
Therm 8000S
Electrical connection | 27
6.4.6 Exhaustion type C
53
Fig. 44
7
Electrical connection
All regulation, verification and safety mechanisms have been
rigorously tested in the factory and are ready for use.
7.1 Connection
▶ Connect the feed cable to an earthed power point.
7.2 Power cable
The appliance is provided with a labelled power cord and
earthed mains plug.
6720608920-29.1AL
Ø 80 mm
Ø 80 mm
Ø 80 / 125 mm
Ø 135 mm est.
DANGER:
Risk of electric shock!
▶ Always disconnect the power supply to
the appliance at the mains before carrying
out any work on the electrical systems and
components.
CAUTION:
Fuse protection!
▶ The appliance should have an
independent connection to the electricity
mains, protected by a differential 30 mA
switch and be earthed. In areas subject to
frequent storms, a storm protector
should be installed.
The electrical connection should be
according to current regulations regarding
domestic electrical installations.
▶ An earth connection is absolutely
essential.
If the power cable gets damaged it must be
replaced by a genuine spare part.