Page 13 from
43 6 720 887 547 “SM FP_ErP MPP Europe 2018/08 en”
4.3
Gas manifold
The gas manifold is a gas distribution pipe with 2 types of injectors as in this burner there
are two distinct primary flames with different air/fuel ratios and during whole burning
process flue temperature is kept low reducing the emission of NOX assured by lean
combustion and the mandatory flame stability ensured by rich flame
Pict. 13 – Gas manifold injectors
This manifold is part of the gas conversion kit and injectors are not to be replaced individually,
so the kit will always supply the complete manifold. The stamp indicates the size of injectors
used for reference.
The Burner design allows to have on the same burner surface:
-
One primary rich flame (oxygen enriched combustion for stabilization) which
corresponds to the injectors with smaller diameter in top of manifold
-
One primary lean flame (lack of oxygen for low NOx emissions) which corresponds to
the injectors with bigger diameter in the bottom of manifold.
Pict.14 – Burner design and working principle
The manifold cover allows the gas supply to the burner over 2 different segments, in order
to assure a wide modulation, range according to the capacity of the appliance,
nevertheless in the MPP models, the segmentation is automatically selected according
power demand.